Installing the Switch
Installation Procedure
2-3
Installation Precautions
Follow these precautions when installing the switch.
Installation Procedure
These steps summarize your switch installation. The rest of this chapter provides details on these steps.
1.
Prepare the installation site (
Make sure the physical environment into which you will be
installing the switch is properly prepared, including having the correct network cabling ready to connect
to the switch and having an appropriate location for the switch. See
for some installation
precautions.
WARNING:
●
The rack or cabinet should be adequately secured to prevent it from becoming unstable and/or falling
over.
Devices installed in a rack or cabinet should be mounted as low as possible, with the heaviest devices
at the bottom and progressively lighter devices installed above.
●
When wall mounting, to meet national and international safety requirements, wall mount with the
network ports facing up. The side vents cannot be placed up or downward.
●
Only trained and qualified personnel are allowed to install or to replace this equipment.
CAUTION:
●
When installing the switch, the AC outlet should be located near the switch and should be easily
accessible in case the switch must be powered off.
●
Ensure that the AC power source circuits are properly grounded.
●
Use only the AC/DC power adapter and power cord (if applicable), supplied with the switch. Use of
other adapters or power cords, including those that came with other Hewlett Packard Enterprise
Networking products, may result in damage to the equipment.
For those switches that use a power cord, if your installation requires a different power cord than the
one supplied with the switch, be sure to use a power cord displaying the mark of the safety agency
that defines the regulations for power cords in your country. The mark is your assurance that the
power cord can be used safely with the switch.
●
Ensure the switch does not overload the power circuits, wiring, and over-current protection. To
determine the possibility of overloading the supply circuits, add together the ampere ratings of all
devices installed on the same circuit as the switch and compare the total with the rating limit for the
circuit. The maximum ampere ratings are usually printed on the devices near the AC power
connectors.
●
Do not install the switch in an environment where the operating ambient temperature might exceed
40°C (104°F). This includes a fully-enclosed rack. Ensure the air flow around the sides and back of
the switch is not restricted. Leave at least 7.6 cm (3 inches) for cooling.
●
Ensure all port covers are installed when the port is not in use.
Содержание OfficeConnect 1850 2XGT
Страница 5: ...iii D Warranty Information D 1...
Страница 6: ...iv...
Страница 14: ...Switch Overview Switch Features 1 8...
Страница 28: ...Installing the Switch Installation Procedure 2 14...
Страница 32: ...Configuring the Switch Where to Go From Here 3 4...
Страница 48: ...Specifications Twisted Pair Cable Connector Pin Outs A 12...
Страница 50: ...Safety and Regulatory Information for the OfficeConnect 1850 Switch Series B 2...
Страница 54: ...Support and Other Resources Documentation feedback C 4...
Страница 56: ...Warranty Information D 2...