
HEWI
installation instruction
M1000_117_ES5400_EN_Vers-002.pdf
M1000.117
Page 2 of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
opener is active, the door can be used by everyone without valid access-rights. At 3 pm a
blackout occures, at half past 3 the power supply returns. The relay isn’t activated any more,
the door can only be opened by people with vaild access-rights.
h) Danger of lock-out or lock-in during installation
Ensure, that during the installation of a wallreader combined with a door-lock, the door can
always be opened manually, even if the wallreader or the door-lock is not working (e.g.
because of incorrect installation). Always make complete function-test after installation.
i) Interferences
Strong electro-magnetic fields (e.g. transformers, tomographs, ...) and transmitters (IT-
networks, telecommunications, ...) near the wallreader can cause malfunction or
interferences!
Variations
The wallreader ES5400 can be expanded with additional reader-modules ES5401 bzw.
ES5402. These can be connected with the connection-bar. For Details see the installation
manual of those products.
Alternatives
Alternative to the compact-wallreader ES5400 the basis-unit ES5403 in combination with the
reader-module ES5401 or ES5402 can be used.
Preparation of installation
Please check before the installation, if the wallreader you tend to install is suitable for your
application! Check especially:
•
Electrical data (voltage, current, power) of the wallreader and the peripheral devices.
•
Suitability of the wallreader for the environment, especially the protection class IP21.
•
The request at security of the system. In doubt always use an additional reader-module
which will be installed on the „unsecure“ side, in combination with a basis-unit ES5403 or
the compact-wallreader ES5400, installed on the „secure“ side.
•
Please notice, that the security of the whole system always depends on the quality of
peripheral devices such as doors, self-locking-locks, burglar-protected products, or an
alarm-device. In addition the installation has always to consider the supposed attacking-
direction.
•
Please let security-relevant installations be implemented by suitable specialists.
Required Tools
For the installation a screwdriver or a suitable screwdriver for mounting other screws is
needed. To strip the connection cables a cable stripper or a side cutter is needed.
Attention: After the installation the relays are active. Therefore a door opener could be active.
According to the application, a door could be unlocked and used by everyone. If this is not
wished, please programm the wallreader instantaneously using the HEWIKey5
Administration-software, the programming device and the programming key / card. In doubt
please contact the HEWI Servicecenter locking systems, fon +49 5691 82-200.
Ensure, that during the installation of a wallreader combined with a door-lock, the door-lock,
the door can always be opened manually, even if the wallreader or the door-lock is not
working (e.g. because of incorrect installation). Always make a complete function-test after
installation.