WIRING
Hewes Main Harness
To Console
Pin #
Func4on
Wire Color
AWG
1.
Nav Lts (Instrumenta4on)
Grey
16
2.
Nav Lts
Grey
16
3.
Anc Lt (Console)
Grey
/White
16
4.
Anc Lt (T-‐TOP)
Grey
/White
16
Pin C T-‐Top Recept
5.
Horn
Orange
/White
16
6.
Spreader Lt
Blue
/Black
16
Pin A T-‐Top Recept
7.
Overhead Lts
Blue
/
Green
16
Pin B T-‐Top Recept
8.
PANEL GROUND
Black
16
Console Ground Bus
To Accessories
Main Harness
Pin #
Func4on
Wire Color
AWG
1.
Bilge
Brown
14
2.
L/W-‐1
Brown
/White
14
3.
RECIRC-‐1
Red
/White
14
4.
L/W-‐2
Brown
/
Yellow
14
5.
RELEASE WELL
Brown
/
Orange
14
6.
RECIRC-‐2
Red
/
Yellow
14
7.
BUBBLER
Red
/
Orange
14
8.
SALT WATER
Brown
/
Green
14
9.
FRESH WATER
Brown
/Black
14
10.
LIVEWELL LTS
Blue
/White
16
11.
COCKPIT LTS
Blue
/
Red
16
12.
COMPARTMENT LTS
Blue
/Black
16
8 PIN Plug
Pin #
Func4on
1 ACC-‐1
2 ACC-‐2
3 ACC-‐3
4 ACC-‐4
5 ACC-‐5
Wiring
A wiring diagram of your Hewes 18 Redfisher has been included to help troubleshoot any electrical problems or add
additional electronics or electrical connections. We recommend you use a trained marine electrician for all electrical issues.
Inside the console on the starboard side is the ground terminal and the breaker pannel is located in the glove box. All the
grounds lead to the ground terminal and then to the battery via a large diameter black wire.
Always use the recommended breaker/fuse amp sizes. Oversizing or using larger breakers/fuses than required can lead to
electrical shorting and possible damage or destruction of the entire electrical system.
There are open slots on both the ground block and the breaker panel for additional electrical hook-ups. The accessory
switches should be used for any additional hook-ups to protect the entire electrical system. All additional electrical hook-ups
should be performed by a qualified marine electrician.
As a standard practice, we run pull cords forward and aft for any additional wiring needs. For your convenience and ease we
have included a nylon rigging string that runs through the rigging tubes and terminates in the bow. The nylon string will allow
you to easily run any additional wiring through the rigging tubes, thus protecting them from outside elements. We also run a
string aft to the rigging box.