background image

NEPTUN I

Sole cleaning unit
Art.-No.: 84-620

Quantity

1

1

1

1

3 m

1

Pos.

1

2

3

4

5

6

Art. Nr.

MG.03.201

SB.10.022

EM.01.005

ES.09.424

KG.01.021

80.05.001.053

Description

Three-phase 

a.c. motor

Metering pump

Solenoid valve,

G1/2“-24VAC

Safety push

button

Hose,

Di 6 x 1,5 mm

Disk brush,

D 180 mm

Error

- Brush does

not rotate

- No Water

- No 

disinfectant

Cause

- Mains plug not plugged in

- Safety push button defective

- Transformer fuse has triggered

- Motor too hot, thermostat has

triggered

- Gate valve closed

- Hose removed from nozzle

- Hose defective

- Solenoid valve fails to open

- Storage tank empty

- Suction hose not inserted down 

to base

- Metering pump fails to run

- Metering pump runs but no 

delivery

Solution

- Plug in main power supply

- Have button checked by qualified electrician;

replace if necessary

- Have it checked by qualified electrician

- Have it checked by qualified electrician

- Open gate valve (max. pressure 3 bar)

- Make sure hose is fixed tightly to nozzle

- Replace hose

- Replace solenoid valve /notify HEUTE-Service

- Fill up storage tank or replace (refer to 

7. Replacement of tank with disinfectant)

- Insert suction hose down to base (refer to 

7. Replacement of tank with disinfectant)

- Refer to 12. Fuse replacement in metering pump

- Pump hose defective, replace / notify HEUTE-

Service

16. Troubleshooting

17. Spare parts 

(cf. fig. 9)

Fig. 9

Product specifications and design 

subject to change without notice.

All manuals and user guides at all-guides.com

Содержание NEPTUN I

Страница 1: ...eel brush 2 while water 3 and disinfectants 4 will be sprayed onto the rotating brush This way cleansing and disinfection of the soles will take place at the same time 3 Installation Having placed the...

Страница 2: ...e metering pump may only be carried out by qualified electrician Caution Components carry live voltage Volumetric displacement 0 01 0 5 l min Follow disinfectant manufacturer s instructions for dosage...

Страница 3: ...10 Normal Operation Enter platform Firmly grasp retaining bracket Step on grating in the cleaning area with one foot at a time Press safety push button and release the button after cleaning process 11...

Страница 4: ...d it should be cleaned inside and outside 14 Maintenance The machine must only be maintained when turned off and not running Check hoses and make sure they fit tightly and are leak proof otherwiser re...

Страница 5: ...o base Metering pump fails to run Metering pump runs but no delivery Solution Plug in main power supply Have button checked by qualified electrician replace if necessary Have it checked by qualified e...

Страница 6: ...NEPTUN I Sole cleaning unit Art No 84 620 18 Circuit diagram All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 7: ...NEPTUN I Sole cleaning unit Art No 84 620 18 Circuit diagram All manuals and user guides at all guides com...

Страница 8: ...NEPTUN I Sole cleaning unit Art No 84 620 18 Elektro Schaltplan All manuals and user guides at all guides com...

Страница 9: ...ingen Germany Address Weinsbergtalstrasse 2 6 42657 Solingen Germany Phone 49 0 212 3 80 31 13 14 Fax 49 0 212 81 80 85 E mail export heute gmbh de Internet www heute gmbh de Contact us for service sp...