Error
- Brush does
not rotate
- No Water
- No
disinfectant
Cause
- Mains plug not plugged in
- Safety push button defective
- Transformer fuse has triggered
- Motor too hot, thermostat has
triggered
- Gate valve closed
- Hose removed from nozzle
- Hose defective
- Solenoid valve fails to open
- Storage tank empty
- Suction hose not inserted down
to base
- Metering pump fails to run
- Metering pump runs but no
delivery
Solution
- Plug in main power supply
- Have button checked by qualified electrician;
replace if necessary
- Have it checked by qualified electrician
- Have it checked by qualified electrician
- Open gate valve (max. pressure 3 bar)
- Make sure hose is fixed tightly to nozzle
- Replace hose
- Replace solenoid valve /notify HEUTE-Service
- Fill up storage tank or replace (refer to
7. Replacement of tank with disinfectant)
- Insert suction hose down to base (refer to
7. Replacement of tank with disinfectant)
- Refer to 12. Fuse replacement in metering pump
- Pump hose defective, replace / notify HEUTE-
Service