5. Water drainage
(cf. fig. 4)
Dirty water is drained off through the pipe socket (1)
to the floor.
Pipe socket diameter outside 70 mm, inside 66
mm, length 58 mm.
6. Power connection
The machine comes with a cord of approx. 4m
length, fitted with a 5-pole CEE connector (16 A).
The customer must provide an appropriate CEE
socket installed (400 VAC/16 A).
Motor / wheel brush rotates clockwise.
7. Replacement of disinfectant tank
(cf. fig. 5)
- Place tank (1) with disinfectant next to the machine.
- Insert hose (2) into the tank down to base level;
avoid kinks and bends.
- Press and continue to hold down the safety push
button (3) and high-speed push button (4) on
metering pump (5) until disinfectant flows out
of the spray tube (6) without forming bubbles;
afterwards release (3) and (4).
8. Metering pump adjustments
- Opening of the metering pump may only be carried
out by qualified electrician.
- Caution! Components carry live voltage
- Volumetric displacement 0,01 - 0,5 l/min
- Follow disinfectant manufacturer's instructions
for dosage and take samples
8.1 Increase dosage
(cf. fig. 6)
- Loosen cover screws and take off cover (1) of
metering pump
- Turn “Hub” adjuster (2) clockwise with a screwdriver
- Remove pressure hose (3)
- Press safety push button (4) and place measuring
cup (5) underneath the pressure nozzle (6)
- Adjust “Hub” (2) according to measurement results
- Re-assemble in reverse order
8.2 Decrease dosage
(cf. fig. 7)
- Loosen cover screws and take off cover (1) of
metering pump
- Turn the “Hub” adjuster (2) counter-clockwise with
a screwdriver
- Remove pressure hose (3)
- Press safety push button (4) and place measuring
cup (5) underneath the pressure nozzle (6)
- Adjust “Hub” (2) according to measurement results
- In case the dosage is still too high when using
setting "Hub=1" adjust "Frequenz" (7) counter-
clockwise
- Re-assemble in reverse order