background image

Hettich Marketing- und Vertriebs GmbH & Co. KG · Vahrenkampstraße 12 -16 · 32278 Kirchlengern · Téléphone + 49 52 23/77-0 · www.hettich.com

Hettich Marketing- und Vertriebs GmbH & Co. KG · Gerhard-Lüking-Straße 10 · 32602 Vlotho · T49 5733 798-0 · www.hettich.com

6

1

1

2

2
3

4

4

The function provides an easy way of adjusting the desk top to a higher

position. To do this, proceed as follows:

The function provides an easy way of adjusting the desk top to a lower

position. To do this, proceed as follows:

Press the

and keep it pressed until the desk

desk top up button

top reaches the height you want.

Press the

and keep it pressed until the

desk top down button

desk top reaches the height you want.

Upward desk top movement

Upward desk top movement

Downward desk top movement

Downward desk top movement

Memorising a desk top position

Display LegaDrive Touch

Display is locked

(key symbol)

Activating and deactivating by swiping to the left or right.

Move the desk top to any position in the lower half of the

travelling range to deactivate the pedestal stop or to any

position in the upper half of the travelling range to
deactivate the shelf stop. To do this, use the

desk position

down

desk position up

or

buttons until the chosen position

is reached.

Move the desk top to the position you wish to use as the new

pedestal stop / shelf stop position.
To do this, press the

or

desk position down

desk position up

buttons until the chosen position is reached.

Pedestal stop and shelf stop positions

Pedestal stop and shelf stop positions

1.

1.

These two features can be used to limit the desk's travelling range (e.g.

where a pedestal is standing under the desk). A pedestal stop position can be

set in the lower half of the travelling range, a shelf stop position in the

upper half. If a pedestal stop position is set, this is used as the new end

position; a shelf stop position functions as a new upper end position for the

travelling range.

To

a pedestal stop / shelf stop position, proceed as follows:

deactivate

To

a pedestal stop / shelf stop position, proceed as follows:

memorise

Note

These steps must be performed separately for a

pedestal stop position and a shelf stop position.

Simultaneously press the

and

desk position up

desk position

down

buttons and keep both buttons pressed for approx. 10

seconds. The control unit clicks

when the position has

once

been deactivated.

Simultaneously press the

and

desk position up

desk position

down

buttons and keep both buttons pressed for approx.

10 seconds. The control unit clicks

the position

twice once

has been memorised.

2.

2.

or

or

and

and

3

Memorising a desk top position

This function memorises a defined desk top height (one desk top height can
be memorised per

). To memorise a desk top

memory position button

position, proceed as follows:

Move the desk top to the desk top position you want.

2

Press the

save button.

The display shows

.

S –

Press the chosen

(e.g. 2).

memory position button

The display shows

.

S 2

The desk top position setting will now be memorised on the

memory position button

selected. You will hear the control

unit click twice and the memorised desk top position will be

displayed after approx. 2 seconds.

The display shows this position (e.g. 73cm).

5

Plug detection

6

7

Auto Detect Number of Drives

Changing desk height unit (cm or inch)

9

Returning control unit to factory settings (S0 menu)

8

Manual reset

SAVE

en

Содержание LegaDrive Touch Comfort FX

Страница 1: ...Comfort FX WICHTIG VOR GEBRAUCH SORGF LTIG LESEN AUFBEWAHREN F R SP TERES NACHSCHLAGEN en Installation instructions Handset LegaDrive Touch Comfort FX IMPORTANT READ CAREFULLY BEFORE USE KEEP IN A SA...

Страница 2: ...chlengern T l phone 49 52 23 77 0 www hettich com 2 Hettich Marketing und Vertriebs GmbH Co KG Gerhard L king Stra e 10 32602 Vlotho Telefon 49 5733 798 0 www hettich com 2 6 55 8 5mm 10 6mm max 5mm 3...

Страница 3: ...isches einzuschr nken wenn z B ein Container unter dem Tisch steht Eine Container Stop Position kann in der unteren H lfte des Fahrbereiches eingestellt werden eine Shelf Stop Position in der oberen H...

Страница 4: ...ie Taste Tischplatte nach unten Die Displayanzeige beginnt zu blinken Stellen Sie nun mit der Taste oder Tischplatte nach unten Tischplatte nach oben die H henanzeige ein Dr cken Sie die SAVE Taste Nu...

Страница 5: ...hin angezeigt wird dann ziehen Sie das Stromversorgungskabel ab und nach einigen Sekunden wieder ein Tritt der Fehler regelm ig auf ziehen Sie das Stromversorgungskabel ab und wenden Sie sich an den K...

Страница 6: ...travelling range e g where a pedestal is standing under the desk A pedestal stop position can be set in the lower half of the travelling range a shelf stop position in the upper half If a pedestal sto...

Страница 7: ...bination pressed for approx 3 seconds The display shows S 1 Now release the buttons Keep pressing the until the display desk top up button shows S 0 The display shows S 0 Press the save button The con...

Страница 8: ...er resetting unplug the power supply cable and plug it back in again after a few seconds If the fault occurs on a regular basis unplug the power supply cable and contact customer service Unplug the co...

Отзывы: