Heta Scan-Line 900 Скачать руководство пользователя страница 18

18 

Pos.     No.                Name  

 

Qty. 

  

0023-006026 

Vermiculite, front, right 

 1 

  2 

0023-006028 

Vermiculite, rear, bottom 

  3 

0023-006029 

Vermiculite, narrow sid, right 

  4 

0023-006032 

Vermiculite, rear, top 

  5 

0023-006050 

Vermiculite, under Side windows     2 

  6 

0023-006110 

Baffle, two-part, right 

  7 

0023-006467 

Vermiculite, front, left 

  8 

0023-012056 

Vermiculite, smal side, left   

  9 

0023-012057 

Baffle, two-part, left 

10 

0030-0201 

Grate, Ø195 mm 

11 

0030-006009 

Casted bottom 

12 

1013-006262 

Baffle rail 

13 

0023-3017 

Gasket L = 850 

1

14 

4018-0053 

Ash container 

1

8

10

3

9

12 6

4

2

7

1

5

14

11

13

5

scan-line 900 side windows Parts - inside fire chamber

Содержание Scan-Line 900

Страница 1: ...tallation instrUCtions Danish design Danish Quality Danish Production www heta dk EN Scan Line 900 Scan Line 900 SCA Scan line 900 SCA is exempt for use in smoke control areas when burning dry wood PENDING ECODESIGN READY ...

Страница 2: ... 1 22 g kg OGC CEN TS 15883 25 mgC Nm3 ved 13 O2 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combustible materials Rear Without insulation with insulation Sides distance to combustible materials Distance to floor from lower edge of the door Furniture distance Minimum distances in mm 175 175 350 1000 Safety Mechanical resistance to ...

Страница 3: ... NS3058 3059 2 44 g kg OGC CEN TS 15883 88 mgC Nm3 ved 13 O2 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combustible materials Rear Without insulation with insulation Sides distance to combustible materials Distance to floor from lower edge of the door Furniture distance Minimum distances in mm 150 125 400 900 Safety Mechanical res...

Страница 4: ...ed trademark of Heta A S 06 11 2019 0037 1545 Version 1 5 Printed in Denmark Subject to printing errors and changes Operating Instructions Contents Declaration of Performance 2 3 Before installation 5 6 1 Operating instructions 7 1 1 Before using 7 1 2 First firing 7 1 3 Regulating the airflow 7 1 4 Lighting the stove 7 1 5 Refueling 7 1 6 Emptying the ash 8 1 7 Reduced burning 8 1 8 Risk of explo...

Страница 5: ... dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer The packaging must be disposed of as follows Wood is untreated and able to burn in the stove Plastic and cardboard you can drop off at your local recycling center Unpacking the stove 5 ...

Страница 6: ...058 3059 Aus 15A Testrapport 300 ELAB 2276 EN SN No 07 2017 Scan Line 1000 Brændsel Træ Ovnen er godkendt til intermitterende brug Følg fabrikantens brugervejledning Ovnen kan anvendes på røggassamleledning Afstand til brændbart bag ovn 120 mm Afstand til brændbart foran af ovn 1300 mm Afstand til brændbart side af ovn 425 mm Afstand til brændbart under ovn mm Nominel ydelse rum opvarmningsudelse ...

Страница 7: ...ducing negligible amounts of smoke and unburnt hydrocarbons The appliances will only be considered as an exempt appliance if this stop is in place 1 4 Lighting the stove Place two pieces of wood on the bottom Stack kindling on top in layers with air between Set ting fire starter bag brick paraffin on the top now you are ready to light the fuel The flames must work from the top down The use of ligh...

Страница 8: ...ws 40 1 71 The door must be closed during operation Ensure when refueling that the wood is not too close it will cause poorer combustion less heat out put and lower efficiency When refueling be careful to place the fuel into the combustion cham ber gently use the provided glove By not doing so you risk cracking or breaking the vermiculite If there is reduced draft in the chimney we re commend open...

Страница 9: ...of the chimney more often smoke can escape out when the door is open and it gives poor fuel ef ficiency Leading to unnecessary polluting of the environment Good draft will allow the stove to achieve op timal combustion and the highest possible ef ficiency Heta wood stoves are constructed so that it itself provides an optimal blend of com bustion air This provides a high efficiency heat clean glass...

Страница 10: ...age in the form of smoke emissions and reduces the risk of chimney fires If the wood is damp and inadequately seasoned a large proportion of the energy in the fuel will be used to vaporize the water and this will all disap pear up the chimney Thus it is important to use dry well seasoned wood for eg wood with a moisture content of less than 20 Achieve this by storing the wood for 1 2 years before ...

Страница 11: ...ust of course always provide the minimum draft necessary to ensure that it is possible to regulate the fire Please note how ever that chimney draft is dependent on the weather conditions In high winds the draft can become so powerful that it may be necessary to fit a damper in the flue gas pipe to regulate the draft When cleaning the chimney soot and other deposits may come to fall on the baffle p...

Страница 12: ...ning ash bucket C VI C Cleaning of the firebox C VI C Checking switch gasket for door C S VI C S Checking changing gasket for glass C S VI C S Checking switch gasket for ashpan C S VI C S Checking changing gasket for flue pipe C S VI C S Checking changing vermiculite C S VI C S Lubricate hinges L VI L Lubricate lock L VI L Lubricate Ash pan L L For the lubricant used a heat resistant product 300c ...

Страница 13: ...n chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe if necessary The door or ash pan drawer seal is defective While cold close a piece of paper in the door the seal should hold the paper gently in place so it does not fall out by itself Normal wear Rep...

Страница 14: ... 3 4 5 6 1 2 3 4 4 5 6 14 1 17 Scan Line 900 Cleaning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Replace in reverse order Starting with Fig 6 ...

Страница 15: ...900 Side windows Cleaning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks Replace in reverse order Starting with Fig 5 5 ...

Страница 16: ...d Testing is conducted with the combustion air open 31 for Scan Line 900 40 for Scan Line 900 Side windows Oventype Stove Minimum dimensions in mm Norwegian fire wall Distance to fire wall with 108 mm brick Rear the stove uninsulated flue pipe At the side uninsulated flue pipe Length of fire wall forward in front of oven Length of fire wall next to oven Scan Line 900 50 150 500 100 Scan Line 900 S...

Страница 17: ... Vermiculite side right 1 3 0023 006465 Vermiculite side left 1 4 0023 011495 Baffle 1 5 0023 012044 Baffle small 1 6 0023 012060 Vermiculite rear top 1 7 0023 012061 Vermiculite rear right 1 8 0023 012062 Vermiculite rear left 1 9 0030 0201 Grate Ø195 mm 1 10 0030 006009 Casted bottom 1 11 0023 3017 Gasket L 850 1 12 4018 0053 Ash container 1 ...

Страница 18: ...nder Side windows 2 6 0023 006110 Baffle two part right 1 7 0023 006467 Vermiculite front left 1 8 0023 012056 Vermiculite smal side left 1 9 0023 012057 Baffle two part left 1 10 0030 0201 Grate Ø195 mm 1 11 0030 006009 Casted bottom 1 12 1013 006262 Baffle rail 1 13 0023 3017 Gasket L 850 1 14 4018 0053 Ash container 1 8 10 3 9 12 6 4 2 7 1 5 14 11 13 5 Scan Line 900 Side windows Parts Inside fi...

Страница 19: ...d head rivet 1 8 0016 007188 Spring for handle 1 9 0016 007198 Close roller 1 10 0021 006404 Glass 1 11 0023 012405 0023 3008 Glass gasket ø12 L 1 84 m 1 12 0023 012407 0023 3010 Textile glass 6 mm with adhesive black L 1 3 m 1 13 0023 012408 0023 3010 Textile glass 6 mm with adhesive black L 0 36 m 1 14 0030 005956 Stove door 1 15 0030 007183 Handle 1 16 1013 007187 Bracket for door handle 1 17 1...

Страница 20: ...ventilation 22 2 5 Stovedrawings measurments 23 2 6 Connecting direct air below or behind 24 2 7 Installing the HAC unit 24 2 8 Clearances for installation EN 13 240 25 2 9 Changing to a back flue outlet 26 3 Appendix A 27 Remember The stove and chimney installation must comply with local regulations including those referring to national and European standards ...

Страница 21: ...n support the weight of the stove and a top mounted steel chimney In front of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable national and local regulations and must protect against any impact from embers that might fall out of the stove Protecting your floor f...

Страница 22: ... approved materials may be used from the ventilation unit to the air inlet vent The air inlet vent must be fitted correctly and insulated to prevent formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into the open air please note that the grille must be fitted with suitable wind protection There must be no risk that the grille can get clog...

Страница 23: ...ne 900 Stone 1191 515 73 443 40 ø100 1167 1060 218 421 181 1211 515 73 443 40 1167 181 421 ø100 1060 218 Scan Line 900 Side windows Scan Line 900 Stone Side windows 1191 515 73 443 40 ø100 1167 181 421 1060 218 1211 515 73 443 40 1167 218 1060 181 421 ø100 ...

Страница 24: ... Flexi pipe not included Air intake ø100 Flexi pipe to the floor Flexi pipe back outlet Direct air supply The dimensions of the direct air supply pipe may not be less than ø100 mm the draught in the flue depends on this air for optimal combu stion Heta recommends max 4 meters of direct air pipe with max 3 90 bends and a min of ø100 mm HAC KIT 5032 0102 Flexi pipe to the floor Air intake ø100 HAC m...

Страница 25: ...stance to firewall with 108 mm brick A Rear the sto ve insulated uninsulated flue pipe B At the side C Over oven D To furnitures E Corner distance F Rear the stove uninsulated flue pipe G At the side uninsu lated flue pipe H Length of fire wall for ward in front of oven I Length of fire wall next to oven Scan Line 900 175 175 350 390 1000 100 50 150 500 100 Scan Line 900 Side windows 125 150 400 3...

Страница 26: ...26 2 9 Changing to a back outlet Steel model with casted top 1 2 3 ...

Страница 27: ...ction 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulatory Reform Scotland Act 2014 In Wales and Northern Ireland these are authorized by regulations made by Welsh Ministers and by the Department of the Environment respectively Further information on the requirements of the Clean Air Act can...

Страница 28: ...28 ...

Отзывы: