LOCATION AND INSTALLATION/VENTILATION

 

(CONTINUED)

BACKGUARD AND ACCESSORIES

Sheetmetal accessories such as the backguard, and areas at the rear of the rangetop may have sharp 

edges.  Wear work gloves while handling and installing these items.

BACKGUARD

Your Hestan rangetop is supplied at the factory with an Island Trim backguard.  See Table 1 in the 

APPENDIX section of this manual for other backguard options available from your Hestan dealer.  

Selection of the appropriate backguard depends on the installation location and adjacent materials, 

and the type of vent hood to be used.  Installation instructions are included with the backguard kit.  

A LOW OR TALL BACKGUARD IS REQUIRED WHEN INSTALLING THE RANGETOP AGAINST A 

COMBUSTIBLE SURFACE - THE ISLAND TRIM IS NOT SUITABLE.

The top of the backguard serves as an exhaust vent to remove heat from under the rangetop.  DO 

NOT BLOCK or obstruct the top of the backguard.  DO NOT touch the top of the backguard during 

appliance operation as it may get hot.  Allow sufficient time to cool before touching or cleaning this 

area.  DO NOT position plastic or other heat-sensitive items nearby which could melt or burn.

CAUTION

CAUTION

VENTILATION REQUIREMENTS

It is strongly recommended that this appliance be installed with a Hestan vent hood.  Due to the high 

heat output of this rangetop, it is very important that the hood and ductwork installation meets local 

building codes and is installed by a qualified technician.  
Do not use a down-draft style ventilation system.
Do not mount a microwave oven/ventilator combination above the rangetop.  These type of units do 

not have sufficient airflow to remove the high heat output of this rangetop and were not tested with 

this type of appliance.  

For non-Hestan approved vent hoods, the vent hood and/or blower unit must be rated for 1 CFM  

[1.7 m³/hr] for every 100 BTU [.03 kW].
•  If the rangetop has a 12” Griddle, add an additional 200 CFM [340 m³/hr] to the blower capacity.

For island applications, it is recommended to use a vent hood that is 6” [15.2 cm] wider than the 

appliance, to allow for 3” [7.6 cm] of overlap on the left and right of the appliance.
Keep duct runs as short and straight as possible.  Elbows and transition fittings reduce airflow 

efficiency.  Hestan recommends keeping the duct run under 50 ft. [15.2 m].  

CONSULT WITH YOUR HESTAN DEALER ON SELECTING THE APPROPRIATE 

VENT HOOD FOR YOUR HESTAN APPLIANCE. 

Содержание KRT364GD-LP

Страница 1: ...INDOOR COOKING Professional Rangetop KRT Installation Manual ...

Страница 2: ... store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS 1 Do not try and light any appliance 2 Do not touch any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 5 If you cannot reach your gas supplier call the f...

Страница 3: ... installing or servicing appliance Before turning power ON be sure all controls are in the OFF position Failure to do so can result in electrical shock or death ELECTRICAL GROUNDING This appliance must be grounded Grounding reduces the risk of electric shock in the event of a short circuit Read the ELECTRICAL CONNECTIONS section of this manual for complete instructions This appliance is equipped w...

Страница 4: ...EN MODEL NUMBERS RANGETOP MODELS MODEL NO DESCRIPTION CIRCUIT BREAKER REQUIRED KRT365 NG LP 36 RANGETOP WITH 5 BURNERS 15 Amp KRT364GD NG LP 36 RANGETOP WITH 4 BURNERS GRIDDLE 15 Amp KRT485GD NG LP 48 RANGETOP WITH 5 BURNERS GRIDDLE 15 Amp ...

Страница 5: ...RNIA PROPOSITION 65 WARNING WARNING This product can expose you to chemicals including carbon monoxide which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov RATING LABEL The rating label contains important information about your Hestan appliance such as the model and serial number gas type and manifold pressure electrical rating the BTU rating ...

Страница 6: ...n an easily accessible location for servicing of the rangetop Make sure all users of the rangetop know where this shut off is located and how to shut off the gas Any openings in the wall or floor behind the appliance must be sealed The Installation Clearances on the following pages show where the G and E zones should be located The rangetop is designed to be installed nearly flush to the rear wall...

Страница 7: ...SIDE VIEW NOTES SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES G IS GAS CONNECTION ZONE ON REAR WALL MOUNT SHUT OFF VALVE IN THIS ZONE FOR EASY ACCESS WHEN RANGETOP IS INSTALLED E IS ELECTRICAL SUPPLY ZONE W IS APPLIANCE OPENING V IS MIN CLEARANCE TO REQUIRED VENTILATION HOOD OR COMBUSTIBLE SURFACE DIMEN...

Страница 8: ...WITH ISLAND TRIM COOKING SURFACE APPLIANCE TOP COMBUSTIBLE MATERIALS COMBUSTIBLE MATERIALS INSTALLATION CLEARANCES WITH ISLAND TRIM FRONT VIEW SIDE VIEW NOTES SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES G IS GAS CONNECTION ZONE ON REAR WALL MOUNT SHUT OFF VALVE IN THIS ZONE FOR EASY ACCESS WHEN RANGET...

Страница 9: ...T position plastic or other heat sensitive items nearby which could melt or burn CAUTION CAUTION VENTILATION REQUIREMENTS It is strongly recommended that this appliance be installed with a Hestan vent hood Due to the high heat output of this rangetop it is very important that the hood and ductwork installation meets local building codes and is installed by a qualified technician Do not use a down ...

Страница 10: ...restoring power at the supply panel breaker be sure all controls are in the OFF position GAS CONNECTION GAS SUPPLY The local gas authority or supplier should be consulted at the installation planning stage in order to establish the availability of an adequate supply of gas NG or LP If it is a new installation have the gas authorities or supplier check the meter size and piping to assure that the u...

Страница 11: ...d by a qualified technician HIGH ALTITUDE KITS If you live in a high altitude area 2 000 ft 610 m or more above sea level your appliance may require different orifices for proper combustion and performance You will need to contact Hestan Customer Service to arrange a service call High Altitude kits must be installed by a qualified technician Please have your model and serial number information rea...

Страница 12: ... on Check all connections from the supply line up to regulator connection at the rear of the appliance Soap bubbles will appear where a leak is present If a leak is present immediately turn off gas supply tighten any leaking fittings turn the gas supply back on and recheck If you cannot stop a gas leak turn off the gas supply and call the dealer where you purchased your appliance Do not use the ap...

Страница 13: ...l eventually stabilize like those shown in the image below If after a few minutes the flames continue to burn mostly yellow verify that the burner head is properly installed on the base then retest Use caution when handling the burner heads They can be very hot Turn down the control knob to the simmer setting to check function Check each burner individually then check they operate satisfactorily w...

Страница 14: ... 2018 Hestan Commercial Corporation 12 EN APPENDIX ...

Страница 15: ...ÉRENCE FUTURE Ne pas entreposer ou utiliser d essence ou tout autre liquide ou gaz inflammable à proximité de cet appareil ou de tout autre appareil EN PRÉSENCE D UNE ODEUR DE GAZ 1 Ne tenter d allumer aucun appareil 2 Ne toucher à aucun commutateur électrique 3 N utiliser aucun téléphone dans l immeuble 4 Appeler immédiatement le fournisseur de gazà partir d un téléphone situé à l extérieur del i...

Страница 16: ...SQUE DE CHOC ÉLECTRIQUE Débranchez l alimentation avant d installer ou d entretenir l appareil Avant de le mettre sous tension assurez vous que toutes les commandes sont en position OFF Ne pas le faire peut entraîner un choc électrique ou la mort MISE À LA TERRE ÉLECTRIQUE Cet appareil doit être mis à la terre La mise à la terre réduit le risque de choc électrique en cas de court circuit Lisez la ...

Страница 17: ... DE CUISSON NO MODÈLE DESCRIPTION DISJONCTEUR REQUIS KRT365 NG LP TABLE DE CUISSON 36 po À 5 BRÛLEURS 15 Ampères KRT364GD NG LP TABLE DE CUISSON 36 po À 4 BRÛLEURS ET PLAQUE CHAUFFANTE 15 Ampères KRT485GD NG LP TABLE DE CUISSON 48 po À 5 BRÛLEURS ET PLAQUE CHAUFFANTE 15 Ampères ...

Страница 18: ... EN GARDE AVERTISSEMENT Ce produit peut vous exposer à des produits chimiques y compris le monoxyde de carbone qui est reconnu dans l État de Californie comme causant le cancer Pour plus d informations visitez www P65Warnings ca gov PLAQUE SIGNALÉTIQUE La plaque signalétique donne des informations importantes sur cet appareil Hestan telles que les numéros de série et de modèle le type de gaz et la...

Страница 19: ... que tous les utilisateurs de l appareil savent où se trouve cette fermeture et comment couper le gaz Toute ouverture dans le mur ou le plancher derrière l appareil doit être scellée Les dégagements d installation sur les pages suivantes indiquent où les zones G et E doivent être situées La table de cuisson est conçue pour être installée près du mur arrière Il peut être nécessaire de repositionner...

Страница 20: ...PLUS HAUT QUE LES SURFACES DES PLANS DE TRAVAIL CONTIGUS G INDIQUE LA ZONE DE RACCORDEMENT DE GAZ SUR LE MUR ARRIÈRE MONTER LE ROBINET D ARRÊT AUSSI HAUT QUE POSSIBLE DANS CETTE ZONE POUR EN FACILITER L ACCÈS QUAND LA TABLE DE CUISSON EST EN PLACE E EST LA ZONE D ALIMENTATION ÉLECTRIQUE W INDIQUE L OUVERTURE DESTINÉE À L APPAREIL V INDIQUE LE DÉGAGEMENT MIN PAR RAPPORT À LA HOTTE DE VENTILATION RE...

Страница 21: ...S VUE DE FACE VUE DE CÔTÉ LES DIMENSIONS ENTRE CROCHETS SONT EN CM REMARQUES LES ZONES OMBRÉES INDIQUENT LES ENDROITS OÙ LES MATÉRIAUX COMBUSTIBLES SON PROHIBÉS LE DESSUS DE L APPAREIL DOIT ÊTRE AU MÉME NIVEAU OU PLUS HAUT QUE LES SURFACES DES PLANS DE TRAVAIL CONTIGUS G INDIQUE LA ZONE DE RACCORDEMENT DE GAZ SUR LE MUR ARRIÈRE MONTER LE ROBINET D ARRÊT AUSSI HAUT QUE POSSIBLE DANS CETTE ZONE POUR...

Страница 22: ...ords de transition réduisent l efficacité du flux d air Hestan recommande de maintenir la longueur du conduit à moins de 50 pieds 15 2 m CONSULTEZ VOTRE CONCESSIONNAIRE HESTAN POUR CHOISIR LA HOTTE DE VENTILATION APPROPRIÉ POUR VOTRE APPAREIL HESTAN DOSSERET ET ACCESSOIRES Les accessoires en tôle tels que le dosseret et les zones à l arrière de la table de cuisson peuvent avoir des bords tranchant...

Страница 23: ...reil supplémentaire à l écart de façon à ce qu il ne puisse pas s accrocher aux éléments sous votre table de cuisson 3 Avant de rétablir l alimentation sur le panneau d alimentation disjoncteur assurez vous que toutes les commandes sont en position OFF RACCORDEMENT DE GAZ ALIMENTATION EN GAZ Consulter les autorités locales responsables ou le fournisseur lors de la phase de planification de l insta...

Страница 24: ...fectuée que par un technicien qualifié KITS DE HAUTE ALTITUDE Si vous vivez dans une région à haute altitude c est à dire au moins 2000 pi 610 m au dessus du niveau de la mer votre appareil peut exiger des orifices calibrés différents pour une combustion et un rendement appropriés Vous devrez contacter le service clientèle de Hestan pour faire effectuer cette opération Les kits Haute Altitude doiv...

Страница 25: ...Ouvrir l arrivée de gaz Contrôler tous les raccordements depuis la conduite d alimentation jusqu à la connexion du détendeur à l arrière de l appareil Des bulles de savon se formeront à l emplacement d une fuite En cas de fuite couper immédiatement l arrivée de gaz resserrer tout raccord qui fuit rouvrir l arrivée de gaz et recommencer le contrôle S il s avère impossible d arrêter une fuite de gaz...

Страница 26: ...lamme de chaque brûleur selon les descriptions ci dessous Les flammes doivent être stables et ne pas danser ni s arracher des orifices du brûleur La flamme peut devoir brûler pendant quelques minutes pour purger les conduits de gaz des impuretés Celles ci apparaissent comme des pointes oranges intermittentes ou même de minuscules étincelles dans la flamme Ceci est normal et la flamme finira par se...

Страница 27: ...FR 2018 Hestan Commercial Corporation 12 APPENDICE ...

Страница 28: ...ommercial Corporation 3375 E La Palma Ave Anaheim CA 92806 888 905 7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE CONSERVEZ CE MANUEL POUR UNE RÉFÉRENCE FUTURE 2018 Hestan Commercial Corporation P N 020058 REV A ...

Отзывы: