
© 2021 Hestan Commercial Corporation
17
EN
USING THE RANGETOP
BURNER CONTROL KNOBS
BURNER CONTROL KNOBS
Each sealed burner has its own control knob. The symbol
below each knob indicates which burner is controlled by each
knob. Push and turn LEFT (counter-clockwise) to HI to ignite
the flame, then turn to the desired flame setting.
SMART BURNER
SMART BURNER
TM
TM
CONTROL KNOB
CONTROL KNOB
The Smart Burner
TM
features a special control knob which
communicates with Hestan Cue cookware via
Bluetooth
®
wireless technology. This feature provides a unique
thermostatic control of the heating, as well as traditional
manual heat control for Cue and non-Cue pans. Please read the
Smart Burner
TM
section of this manual for more information.
BURNER TYPES & OUTPUT
BURNER TYPES & OUTPUT
This table indicates the type and
output of each sealed burner. Dual-
flow burners have an inner and outer
row of ports, with a simmer function.
The single-flow burner (some models)
is similar to a commercial burner and
features very high output, and a low,
but no simmer function.
RE-IGNITION
RE-IGNITION
Each sealed burner has its own electronic spark-ignition module with flame-sensing technology and
automatic re-ignition capability. If any burner should blow out, the igniter automatically re-lights the
burner.
Each burner should light in less than 4 seconds. Once lit, the sparking will stop. On very low simmer,
an occasional sparking may occur. This is usually due to a breeze in the room. If an igniter continues to
spark even with a flame present, there could be an electrical wiring issue, or some other problem. See the
TROUBLESHOOTING section of this manual for more information.
Note: The Smart Burner
TM
may take longer to light as the system runs a self check prior to ignition. No
gas will flow during this self check process. Sparking should not exceed 4 seconds.
DO NOT touch the burner or the igniters while sparking is occurring. A shock hazard or burns could
occur.
MANUAL LIGHTING / POWER FAILURE
MANUAL LIGHTING / POWER FAILURE
THE OVEN, GRIDDLE, AND SMART BURNER
TM
CANNOT BE USED DURING A POWER FAILURE.
Each sealed burner can be manually lit in the event of a power failure. It is necessary to light each burner
individually.
If a power failure occurs WHILE you are using the sealed burners, turn all the knobs to the OFF position -
then light manually with a match or fireplace lighter.
Position the match or fireplace lighter at the port nearest the igniter, then turn the knob to HI until the
flame is lit. Wait until the flame has lit all the way around the burner before adjusting the knob to LOW
or SIMMER.
IF YOU SMELL GAS, turn all control knobs to OFF - check the precautions listed in the SAFETY section
of this manual.
DUAL-FLOW
(FRONT)
OUTPUT
(BTU/hr)
DUAL-FLOW
(REAR)
OUTPUT
(BTU/hr)
SINGLE
GRIDDLE
FLOW
OUTPUT
(BTU/hr)
HI
23000
HI
15500
MAX
30000
LOW
4200
LOW
4200
LOW
4200
15000
GRIDDLE
15000
SIMMER HI
1500
SIMMER HI
1500
SIMMER LOW
500
SIMMER LOW
500
DUAL-FLOW
(FRONT)
OUTPUT
(BTU/hr)
DUAL-FLOW
(REAR)
OUTPUT
(BTU/hr)
SINGLE
FLOW
OUTPUT
(BTU/hr)
HI
23000
HI
15500
MAX
22000
LOW
4200
LOW
4200
LOW
SIMMER HI
1500
SIMMER HI
1500
SIMMER LOW
600
SIMMER LOW
600
BURNER OUTPUT - PROPANE
4200
BURNER OUTPUT - NATURAL GAS
SMART
BURNER
TM
20000
SMART
BURNER
TM
20000
Содержание KRD
Страница 1: ...INDOOR COOKING Dual Fuel Range KRD Dual Fuel Smart Range KRDS Use Care Manual...
Страница 4: ......
Страница 68: ......