HES 9500 Series Скачать руководство пользователя страница 4

4

Frame Preparation

9"

[228.6]

CE

N

TERLINE OF L

ATCHBO

LT

THIS EDGE TOWARD DOOR 

2X MOU

N

TING HOLE

LOC

ATIONS FOR

1/4-20 UNC CAP SCREWS

7/8"

[22.2]

4-1/8" [1

04.8]

1-3/4"

[44.5]

 

CLEARANCE FOR POWER WIRING 

Final 

Lo

ckdown 

Feature 

10-32 UNF (96

00 OPTIONAL)

 1

-1/

16"

[2

7.0]

4-1/8" [1

04.8]

4X

[33.3]

1-5/

16"

[33.3]

1-5/

16"

1-3/4”

[44.5]

5/8”

[17.4]

7/8”

[22.2]

3/4”

[19.1]

9”

[228.6]

4-1/2”

[114.3]

8-1/4”

[209.6]

             #1/4-20

MOUNTING SCREWS

SETSCREW LOCATION

1. Loosen the two #1/4-20 mounting screws.

2. Adjust strike to appropriate horizontal position.

3. Tighten the two #1/4-20 mounting screws.

4. Lock down adjustment by tightening the setscrews.

9500/9600 DIMENSIONS

HORIZONTAL ADJUSTMENT

Inches [mm]

   3/4”  [190]

CLEARANCE FOR LBM/LBSM WIRING 

   3/4”  [190]

© 

2009 HES, Inc.

3055006.002 rev A

Содержание 9500 Series

Страница 1: ...0 feet or less 200 300 feet 300 400 feet 14 gauge 12 gauge 14 gauge 18 gauge 18 gauge 16 gauge 2 4 1 ASSA ABLOY the global leader in door opening solutions Product Components 10 32 Final Lockdown Screw 12 24 Volt Pigtails 1 2 9500 9600 Electric Strike Body 1 4 20 x 1 Mounting Screws 3 4 ELECTRICAL RATINGS FOR SOLENOID CONTINUOUS DUTY 12VDC 26 6 45 24VDC 106 6 225 Resistance in Ohms Amps Solenoid v...

Страница 2: ...ransformers operate at higher levels than listed Any input voltage exceeding 10 of the solenoid rating may cause severe damage to the unit and will void the warranty Prepare Frame 4 Prepare the door jamb using the Installation Template located on page 4 with the exception of the 10 32 UNF threaded hole 5 Connect power wires and attach electric strike to jamb using the 1 4 x 20 cap screws provided ...

Страница 3: ... position as pictured away from the center of the strike in Figure 2 There are screws on both the left and right side of strike Both pairs of screws must be repositioned to convert the strike to Fail Safe Operation 3 Tighten both sets of 4 40 screws after they have been moved to the Fail Safe Operation position 4 For 9500 series strikes remove the Listed Fire Rated Hardware label if the strike is ...

Страница 4: ...4 8 4X 33 3 1 5 16 33 3 1 5 16 1 3 4 44 5 5 8 17 4 7 8 22 2 3 4 19 1 9 228 6 4 1 2 114 3 8 1 4 209 6 1 4 20 MOUNTING SCREWS SETSCREW LOCATION 1 Loosen the two 1 4 20 mounting screws 2 Adjust strike to appropriate horizontal position 3 Tighten the two 1 4 20 mounting screws 4 Lock down adjustment by tightening the setscrews 9500 9600 DIMENSIONS HORIZONTAL ADJUSTMENT Inches mm 3 4 190 CLEARANCE FOR ...