DIAGRAM 3: LATCHBOLT MONITOR
3
Installation Diagrams
LBM WIRING
White
Orange Normally Open
Green
Normally Closed
Common
DIAGRAM 4: STRIKE MONITOR
DIAGRAM 3: LATCHBOLT MONITOR
Blue
Normally Open
Yellow
Normally Closed
DIAGRAM 5: CYLINDRICAL LOCKSETS
LBSM WIRING
Brown
Blue
Normally Open
Yellow
Normally Closed
Common
DIAGRAM 5: FAIL SAFE CONVERSION
Convert Mode
Figure 1: FAIL SECURE OPERATION
The 9500/9600 series Electric Strike is
pre-set for FAIL SECURE OPERATION as
shown in Figure 1.
1. To convert to Fail Safe Operation, loosen
the 4-40 screws located on the rear of the
strike as shown in Figure 2, but do not
remove them.
2. Move the screws to the Fail Safe Operation
position as pictured (away from the center
of the strike) in Figure 2. There are screws
on both the left and right side of strike. Both
pairs of screws must be repositioned to
convert the strike to Fail Safe Operation.
3. Tighten both sets of 4-40 screws after they
have been moved to the Fail Safe Operation
position.
4. For 9500 series strikes, remove the “Listed
Fire Rated Hardware” label if the strike is
used in the fail safe operation. Using the
9500 in Fail Safe operation negates the fire
rating.
Verify
Verify that both keepers are in Fail Safe
Operation. Both keepers should be
unlocked without power, but lock when
power is applied.
If one or both keepers is still in the Fail
Secure Operation, verify that the 4-40
screws have been moved all the way into the
countersunk hole as illustrated in Figure 2.
Figure 2: FAIL SAFE OPERATION*
White
Orange
Green
Brown
Blue
Yellow