background image

                

items: working states (cool, heat or ventilation), the speed of fan coil, room 

temperature, set-point. There are following keys on 

the panel: On/Off “

 

”, Exchange 

mode (cool, heat or ventilati

on) “

 

”, Select fan speed (high, medium, low or auto) “

 

”, 

set-

point temperature “

” and “

”.

 

H7

990

 

adopt digital control technology with large LCD display, It shows the

 

following 

BASIC FEATURES 

STATUS DISPLAY 

 Room temperature setting 

 Manual or Auto 3-speed changeover 

 Defrost (low temperature protection) 

 IR remote control (Option) 

 Blue Backlight (Option) 

 Working Status: Cool 

, Heat 

, Ventilation 

 Fan Speeds: Low 

, Medium 

, High 


and Auto

.

Room temperature display  

Temperature setting display 

SPECIFICATIONS 

 Sensing element: 

  NTC 

 Accuracy : 

  ± 1

 

 Set-point range:            5

 to 35

 

 Display range:   

  0

50

 

 Operation environment: 0

45

 

 Operating Humidity:      5

90%RH (non-condensing) 

 Power supply: 

AC 85

260V, 50/60Hz 

 Switch current rating: Resistive: 2A, Inductive: 1A 

 Rated Power: 

 2 W 

 Wirings: Screw-in terminals, each terminal capable of 

accepting 2 x 1.5 mm

2

 or 1 x 2.5 mm

2

 wires

 Housing: ABS + PC Flame Retardant 

 Dimensions: 86 × 86 × 13 mm ( W × H × D ) 

 Hole pitch: 60 mm ( Standard ) 

 Protection Class: IP30 

 Display: LCD 

OPERATION 

 On/Off: Press 

 

” to turn on, press “

 

” again to turn off thermostat and its output. 

 Setting temperature: Press 

” to reduce set-point, press “

” to raise set-point, and 0.5

 changed once. 

 Mode Selection

: Press “

 

” to change system working in cooling “

 

”, heating “

 

” or ventilation “

 

” mode, the related 

icon will flash, and it will be confirmed automatically after 5 seconds. The ventilation function is invalid for 

H

7990 08

.

 Fan Speed Selection 

H7

990 08 

:

P

ress “

 

” to change fan speed among “ (Hi)”,

 

 

          

(

Med)”, “ (Low)” 

     

or

 

“Auto”. 

Under auto  fan  speed 

“Auto”, the  fan-speed  will  be  changed  automatically. Auto  LOW-speed  When  the  difference 

MODEL DENOMINATIONS

 

H7990 08

   

R:

 IR remote function. Blank is invalid. (

Remote controller should be ordered additionally

L:

 Backlight available. Blank is invalid. 

Y:

              Control damper to open or close.

 

DA/DA2: 

Control Motorized Valve (DA: Control 2-wire N.C. FCU valve; DA2: Control 3-wire FCU valve) and 3-speed 

fan; When the temperature reaches the set-point, it will close the Motorized Valve with the fan still running. 

DB/DB2:

 Control Motorized Valve (DB: Control 2-wire N.C. FCU valve; DB2: Control 3-wire FCU valve) and 3-speed 

fan; When the temperature reaches the set-point, it will close the Motorized Valve and Fan both. 

FCV2:

      Control 4 pipe fan coil units, Control two Motorized Valves and 3-speed fan, when the temperature reaches 

the set-point, it will close the Motorized Valves with the fan still running. 

Data sheet for 

H7

990

 08

, Is

sue 0916

HERZ Armaturen Gws.m.b.H

Richard-Strauss-Strasse 22,1230 Vienna, Austria.

1

  

H

ERZ

 H7

990

-08

 Series Thermostat

 

H7

990

 

Series thermostats are available for individual room temperature control

 

in residential, industrial and business premises. Suitable for 2-pipe or 4-pipe Fan Coil 

configuration.  

Отзывы: