TW-800R-SLNX
17
⚫
[Double count protect time] Double count prevention time setting
The receiver can disable the signal from the same transmitter for a period of time after receiving the
signal from the transmitter. This time is called the double count prevention time.
When the receiver receives a signal from the same transmitter during double count prevention time, the
receiver does not process the signal and transmits a “BUSY” signal to the transmitter.When the
transmitter receives the “BUSY” signal, the green LED blinks 4 times.
Available from the following 19 different time settings.
10ms / 100ms / 200ms / 500ms / 1s / 2s / 3s / 4s / 5s / 6s / 7s / 8s / 9s / 10s / 11s / 12s / 13s / 14s / 15s
Default:
100ms
Example) Action performed when double count prevention time is set to 200ms
Double counting is prevented for 200ms from when a signal is received from the transmitter.
*
Note
Do not set the double count prevention time shorter than the external output time.
Even when the receiver receives a signal from the transmitter two times, two external outputs may be
generated without interruption, depending on the setting or receiving timing. LAN output is performed
respectively.
Example) Action performed when output time is set to 200ms and double count prevention time is set to
100ms.
When receiving a signal from the transmitter, the receiver starts to generate an external output. When the
receiver receives a signal from the same transmitter during external output (140ms after starting the
external output), an external output is continuously generated for 200ms from that point, without the external
output turning OFF.
100ms
External output ON
External output OFF
Receive
Receive
200ms
Double count prevention
External output ON
External output OFF
Receive
Receive
Double count prevention
100ms
100ms
140ms
200ms