background image

Select XLS

The Select XLS White panels come with a factory fitted plug. They can be easily wall mounted close to an electrical
socket or can be freestanding. Both methods require the use of either the XLS controls (either the plug in control

T-

PL

or battery control

T-BT

). See controls section.

Plug and Play Options 

simple wall mounting & portable (white panels only)   

Wall mounting (DIY installation)

Mount on the wall using the EASYFIX mounting bracket and
simply

plug in the heater

(only applies to white panels

supplied with a fitted plug).

This is relatively straightforward for a competent DIY person.
The panel will need to be mounted close to an electrical socket
but MUST NOT be mounted immediately below a socket and
no closer than 200mm away from the socket. The SMART-R
box on the rear of the panel should be located at the bottom
of the panel. The panel can be mounted in either landscape or
portrait position (see detailed installation instructions). Be
careful when drilling holes for the EASYFIX mounting bracket
to be clear of electric cables within the walls. If in doubt do not
install and refer to a qualified electrician.

min 200mm

Freestanding / portable use

The Select XLS White panels can be used freestanding or as
portable heaters e.g. for temporary or seasonal heating. For
portable use we strongly recommend the use of Herschel Feet.
These are specially designed to reduce the risk of the heater
falling over and to prevent the bottom of the heater having
direct contact with floor surfaces. Feet are an accessory and
are not supplied with the heater. Contact your dealer or the
Herschel Website for details.

Select XLS Mirrors and Towel Heaters are not suitable for
portable use. They are supplied without plugs and must be
wall mounted and installed by an appropriately qualified
electrician.

min 200mm

Содержание Select XLS Series

Страница 1: ...LS1000W EU Select XLS towel heater XLS500T XLS700T Models Instructions operating mounting and installation guide The product complies with European Safety Standards Low Voltage Directive 2014 35 EC EM...

Страница 2: ...amaged the appliance must be sent for repair to an authorised Herschel Dealer This heater must only be used for the heating of people or buildings The heater is not to be used by children or persons w...

Страница 3: ...t the edge or in the corners of a room Large objects placed in front of the heater will heat up and can prevent effective heat dispersion into the room If you can avoid placing the heater opposite win...

Страница 4: ...be located at the bottom of the panel The panel can be mounted in either landscape or portrait position see detailed installation instructions Be careful when drilling holes for the EASYFIX mounting...

Страница 5: ...mm between adjacent heaters Objects in front of the panel must be at least 400mm away and 200 mm away from the sides The distance from the sides of the heater must always be observed Failure to do so...

Страница 6: ...appliance must take the shortest route to the edge of the heater Ensure that the power cable is not coiled Shorten the power cable if possible and do not place excess cable on the rear of the heater E...

Страница 7: ...will be measured by the XLS controller It is normal to use one controller per room but if it is a large room such as open plan area you may want to consider more than one thermostat controller If ther...

Страница 8: ...eing an override only Controller Bypass The Select XLS panel can be configured to by pass the receiver in cases where an alternative control system is intended to be used e g building management syste...

Страница 9: ...Painting the panel will not affect your warranty for repair or replacement Cleaning and maintenance Cleaning Before attempting to clean the panel unplug the heater isolate the unit from the electrica...

Страница 10: ...room itself is warm that you will feel warm The great thing is that this heat is retained longer and only needs topping up to account for the heat loss escaping from the room In the longer term you w...

Страница 11: ...have no liability for installation costs or consequential loses however incurred The decision to repair or replace will rest solely with Herschel and any replacement will be as close as possible in sp...

Страница 12: ...ion the panel should be moved to the right and then down and to the right again to its secure position portrait mounting or down then left and then down again landscape mounting fig 5 6 Step 5 Mirrors...

Страница 13: ...t 20 36 Actual efficiency target post Lot 20 37 Herschel Select XLS White Panels are compliant if used with a plugin electronic room temperature control such as Herschel T PL Technical Details Nominal...

Отзывы: