T2 Wireless thermostat

Press MENU again to display the ECO mode

temperature. Change the

temperature using the Up and Down buttons.

“SET”

is displayed indicating you

have hanged the setting.

Return to the main page by pressing the Return button.

To select a mode at any time, press the MENU button. This selection will override the
schedule or current temperature setpoint. For example, by selecting Eco mode (using
the MENU button) the T2 can maintain a lower holiday temperature setting until
another mode is selected.

Program Mode

The T2 has a 7 x 1 day timer (Monday to Sunday) with 4 periods per day. Set period 1
as the first temperature of the morning, period 2 is the fallback temperature for the
daytime. Period 3 is the temperature required for the evening and period 4 is the
overnight temperature.

Unlike conventional heating, Herschel Far infrared directly heats the room (the

“Thermal Mass”)

. For areas in frequent use it is more economical to avoid

temperatures dropping too low as the heater will need to be on for a much longer
period to restore temperatures. We recommend overnight setback temperatures of
no lower than 14

°

C and daytime temperatures of 16

°

C and above.

To select Program Mode press MENU until PRG is displayed as the mode. The
schedule will then operate until another mode is selected.

All days

Period 1

0630 21

Period 2

0800 18

Period 3

1800 21

Period 4

2230 16

To alter this schedule:

Press the PRG button for 3 seconds to
start the 7 x 1 day program setting.
The First period of the First day is
selected.

Press the Up or Down button to
change the time of the first period of
the

day’s

program.

Press PRG again to move to the
temperature setting of the first period
and use the Up and Down buttons to
adjust the temperature.

Содержание iQ Heating Controls T2

Страница 1: ...08 2020 onwards Technical Information Power supply T2 2 x AAA Batteries Installation T2 Wall Mounted or free standing Setpoint Range 5 35 C temperature increments 0 5 C Accuracy 0 5 C Ambient tempera...

Страница 2: ...re and will turn them OFF once the desired temperature is reached or exceeded The R2 is the switch that turns your heaters on and off and must be wired to the heaters and mains power The R2 also acts...

Страница 3: ...T2 Wireless thermostat Display Buttons T2 Control Unit Installation T2 Stand alone Wall mounted Initial setup 1 Insert 2 x AAA batteries into the T2...

Страница 4: ...ction under the control of the T2 without SmartLife but LED 1 will always flash slowly red The T2 display will indicate if heating is on or off To pair additional R2s to a T2 1 Switch on the R2 using...

Страница 5: ...he connection for a few seconds longer and when finished will leave you in the management screen for the R2 You can experiment at this point entering commands e g temperature up or down from the App o...

Страница 6: ...c 5 Press the Return button once you have selected the right day Mode Selection and settings The T2 has 3 operating modes Manual ECO and Program Mode Select Manual if you want to set and maintain one...

Страница 7: ...the overnight temperature Unlike conventional heating Herschel Far infrared directly heats the room the Thermal Mass For areas in frequent use it is more economical to avoid temperatures dropping too...

Страница 8: ...radiator and don t want to have the T2 stop the heat before the rest of the room has warmed up negative adjustment needed Or perhaps the T2 is placed in a cold area e g by a window and you want the T2...

Страница 9: ...a warranty claim please visit the Customer Service area of the Herschel Website and follow the Warranty Claim process You will need proof of purchase Note your serial number here for future reference...