Table 1. Electrical Specification
Model
Rated Power
Voltage Current
Frequency
Fuse (Minimum)
CALIFORNIA 2000
2000W
230V
8.7A
50/60Hz
13A
The mounting position of the unit must ensure that any mechanical damage to the flexible cable is unlikely. Any exposed flexible
cable is to hang down (not tied UP) and must have adequate clearance from the heater to prevent scorching or damaging the
cable.
Colour coding used in the supplied mains cable: BROWN wire is to be connected to LIVE (‘L’), the BLUE wire to NEUTRAL (‘N’)
and
the GREEN/YELLOW wire to EARTH (‘E’).
MOUNTING POSITION:
Diagram 1: CALIFORNIA heated area and applications
Middlewave Infrared heat
is characterised by a
strong central beam that
dissipates to a gentler
intensity heated area
outside the central beam.
The zone heated by
CALIFORNIA will increase
in size the higher the
heater is installed from
the floor, but the warmth
experienced from the
heater will be lower.
The mounting height and
intensity should reflect
the intended use of the
heater.
Mount the heater at a
lower height in areas
intended for low physical
activity (for example a
seating area) or areas
subject
to
stronger
airflow (outside or near
open doors).
Mount
CALIFORNIA
higher where less intense
warmth is needed (for
example public spaces
where people are active
or wear warm clothing).
For permanent installation (i.e. not using a stand), the Herschel CALIFORNIA must be located in a position to allow proper and
efficient use but one that ensures hot parts are not touched accidentally. The recommended installation height of the CALIFORNIA
is 2.4m to 3.5m (95
”
-138
”)
from the floor.
Under no circumstances is the unit to be installed at less than 1.8m (71”) from the floor.
Consideration should be given to any temporary or occasional additions such as stages or platforms and adjusted accordingly. For
outdoor use, or other areas with air movement/wind the directional Infrared spread may reduce by 1/3 to 1/2.
Wall mounting swivel brackets are provided with the heater which has been specifically designed to allow this product to be fitted
to a wall with adequate clearances at the back of the unit. Do not mount the heater with any other bracket except those provided.
The sides and ends of the heater must always be at least 300mm
(12”)
away from the nearest wall, ceiling or other structure.