3. Description of the face 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.1 Using of fixed programs 

 

The control unit RT100D will be delivered with 9 fixed programs all this 
programs can be adjusted by the customer. 
The following switches should be pressed to start a fixed program. 

Prog
sichern

Prog

°C

h:m

Tem p2

Tem p1

Zeit 3

Zeit 2

Zeit 1

Ende

Digital-Display

top-temperature

first temperature

fixed programs

choose of 
time and temp

start/stop program

set program to memory

values up

values down

temperature in  °C

time in hours : minutes

main switch

fuse 

4.0 Use of Program Datas 

 
After you have pressed the start switch the control unit will start the program . 
 
The first point of working is the delay time.After you have programmed the delay time 
the controller wait till this time is zero. On the display you will see the value of the 
delay time. 
The control unit starts the fireing program as soon as  the delay time reached zero. 
This feature will be used if you like to start a kiln e.g. in the evening. 
 
The fire-process beginns with the ramp time. The control unit calculats the right 
heating power to bring the kiln slowly to the firtst set point during the ramp time. If the 
ramp time reached zero the kiln will be fired with full power. If the kiln temperature 
reached the top temperature the control unit soak during the soak time. 
After the soak time the controller switchs the kiln of and the kiln temperature will cool 
down. 

Содержание RT 100 D

Страница 1: ...andwerkerpark 1 D 45309 Essen Telephone 49 201 89911 0 Telefax 49 201 89911 20 Email kontakt hermes electronic de Internet http www hermes electronic de 2004 HERMES electronic GmbH OPERATING INSTRUCTIONS Program Controller RT100D ...

Страница 2: ... Controller RT100D Contens page Introduction 3 2 First Start 4 3 Description of the face 3 1 Using of fixed programs 5 3 2 Program Adjustment 7 4 Use of Program Datas 8 5 Error Messages 9 6 Technical Datas 11 Notiz ...

Страница 3: ...ln during fireing Every control unit RT100D is tested and checked for 100 of quality in our company All our control units have an overheating safety relay but if you use the control units you should observe the fireing Do not fire the kiln without observing If you have any problems please have a look into the error list at the end of this manual If you are not able to solve your problems by yourse...

Страница 4: ...0Minutes If thekilnis toslow thecontrol unit shows F1 causes heatingelement is faultyor toold with3PhaseSystems onPhaseis missing Thermocoupleis short connected door switchis not closed Display F2 Istheheatingtimeinthefull power periodelonger than18hours thekilnwill switchedoff andthe displayshows F2 causes heatingelement is faultyor toold with3PhaseSystems onPhaseis missing Display F3 If themeasu...

Страница 5: ...e control unit will start the program The first point of working is the delay time After you have programmed the delay time the controller wait till this time is zero On the display you will see the value of the delay time The control unit starts the fireing program as soon as the delay time reached zero This feature will be used if you like to start a kiln e g in the evening The fire process begi...

Страница 6: ...0 C 500 C 500 C 930 C 400 C 400 C Temp 2 1230 C 1230 C 1230 C 1230 C 800 C 800 C Zeit 3 0h 30 1h 00 1h 00 1h 00 0h 30 1h 00 3 2 ProgramAdjustment If you like to adjust program datas you should use the following description Please load and start your programm see section 3 1 and press the following switches switch start stop switch please press this switch a fewtimes if the right data is displayed ...

Отзывы: