Before proceeding with the table assembly: All electric motors MUST be 
initialized before moving the table in the “UP” direction.  

Please follow the below instructions for proper initialization: 

• 

All Columns (motors) must be plugged into the Control box.

• 

Plug the “Up/Down” Hand switch in to the Control box.

• 

Plug the Control box power cord into a 110 volt grounded outlet.

• 

Hold the “Down” button in until the columns bottom out to the lowest 
position.

• 

Please continue to hold until a “clicking” sound is heard and the 
columns move “slightly” UP.

• 

Once this is completed your system is properly initialized and can be 
operated without harm to the system.

STOP

Do Not Overload Desk 

To prevent table from tipping or collapsing, make sure the desk frame is 
not overloaded by the weight of table top and objects on table. Evenly 
distribute load; excess loads near edges can reduce stability and lead 
to tip over. 

• 

Do not exceed maximum load (including weight of desktop) of 
200 lb. (91Kg) for two-leg configuration.

• 

Do not exceed edge load of 25 lb. when positioning monitors or 
mounting accessories.

• 

Do not sit or stand on table

Use Care When Moving Desk

 

• 

Clear objects and equipment from table before rolling to reduce 
the risk of tipping over.

• 

Adjust the desk to its lowest height before moving

• 

To disconnect, turn all controls to the off position, then remove 
plug from outlet

• 

Do not move a loaded desk

• 

Do not lift the desk by the work surface (desktop)

Do Not Open Electrical Components

Keep Table Frame Dry

Do not attempt to service table components. There are no user-
serviceable parts inside the motor control units or table legs. If 
your table needs service, contact customer service. Never operate 
this furnishing if it has a damaged cord or plug, if it is not working 
properly, if it has been dropped or damaged. Return the furnishing to 
a service center for examination and repair.

Keep all electrical components away from water and high humidity. 
Clean only with a dry or slightly damp cloth. Do not spray cleaning 
solutions directly onto table system. 

Grounding Instructions

This product is equipped with a cord having an equipment-grounding 
conductor and a grounding plug. 

Use only the cord provided

. Make 

sure that the product is connected to an outlet having the same 
configuration as the plug (as shown in Illustration A) that is properly 
installed and grounded in accordance with all local codes and 
ordinances. 

Do not modify the plug provided with the product - if it will not fit the 
outlet, have a proper outlet installed by a qualified electrician.

No adapters are to be used with this product. Keep cord away from 
heated surfaces.

Grounding Pin

Grounded Outlet

Grounded Outlet Box

Содержание Nevi Height Adjustment Table

Страница 1: ...ct Do not change or replace components and accessories provided 1 1 1 1 KEEP AWAY FROM CHILDREN This table system is not designed for use in homes or other areas accessible by small children For indoor commercial office use only BE CAREFUL WHEN ADJUSTING DESK HEIGHT Body parts and property can be caught between the moving work surface and an immobile obstacle such as shelves furniture window sills...

Страница 2: ...ipping over Adjust the desk to its lowest height before moving To disconnect turn all controls to the off position then remove plug from outlet Do not move a loaded desk Do not lift the desk by the work surface desktop Do Not Open Electrical Components Keep Table Frame Dry Do not attempt to service table components There are no user serviceable parts inside the motor control units or table legs If...

Страница 3: ...peat step 3 and tighten Note Some holes may need to be pre drilled Full Length Independent Step 2 Assemble Top Support to the Beam and Column 2 1 Assemble using the M8 x 1 25 x 12mm length screws 4 per column leave screws loose When torque wrench is available tighten fasteners to maximum of 24 Nm 18 Ft Lbs If you do not have access to a torque wrench then tighten fasteners to snug plus a turn Alig...

Страница 4: ...pplier 6 2 Connect the Handswitch HS Cable to the Control Box Step 6 Connect the Motor Cable to the Control Box 6 1 The motor cable plug connection has to click into place If a control box is used which has more plug terminals than needed you have to connect to M1 first The extra terminals can be left open Connections to the control box M1 M2 Connectors for the columns HS Connectors for the handse...

Страница 5: ...1BNX5K D Disassembly for Recycling Materials Identification and Segregation Where possible plastic components are marked with ASTM recycling codes Use these codes to identify material type for recycling Non marked components should be treated as mixed plastic Ferrous metals can be identified using a small magnet for recycling Non ferrous metals should be separated and recycled separately To disass...

Отзывы: