Component Pack Fitting Instructions
Please ensure these instructions are followed carefully-if your
unsure about any aspect of the installation,please consult a
qualified installer. In the event of any problem with the function of
this equipment, please check installation before consulting your
supplier.
Do not use mole grips on plastic nuts.
Do not use a sealing compound as damage may occur to plastic
components.
Do not over tighten plastic nuts
Warning
Push the piston assembly from the bottom, inside the housing of
the siphon & remove the tie wrap from the piston rod (shown in
picture’ A’) insert the C-Link into the piston rod as shown in
picture ‘B’.
Feed the lever through the handle hole & secure in place using
back-nut provided, slide the plastic lever arm over the shaft,
ensure the end of the lever arm lines up over the top of the piston,
remove from shaft cut plastic lever arm to suit ( if applicable),
attach onto C- Link, slide back onto shaft & secure in place using
screw. The diagram ‘K’ shows a low level mechanism when
wedges are required, the chrome/gold wedge is to be fitted
externally on the Cistern.
Secure the fulcrum bracket in place using the screw & flat nut
provided, hook the fulcrum arm onto the C-Link & clip the fulcrum
arm into the fulcrum bracket, attach the high level chain & pull.
Final Commissioning
Before turning on the water supply, check all components are free
moving & all joints are correctly made.
Fill the cistern with water & carefully check for leaks.
Test the overflow by holding the float down, ensure that incoming
water is completely discharged, if not partially close the isolation
valve (Not Supplied) & try again, repeat until all incoming water is
discharged.
Check that the inlet valve shuts off on the water line indicated
inside the Cistern.