9
Maintenance
Replacing the Valves
We advise that your fitting is regularly serviced in hard water
areas to maintain optimum performance.
If your fitting begins to leak the following should be carried
out;
Isolate both hot and cold water supplies to the tap by either:
•
Turning the water supply off at the mains stopcock
•
Turning off the isolation valves to the tap.
1. Unscrew the indices, to reveal the screw and washer and
proceed to remove these with a suitable screwdriver.
2. Remove the handles and unscrew the shrouds.
3. Using a suitable spanner, remove the valves and clean the
base and the seating inside the tap body.
4. Replace the valves. Please visit
www.heritagebathrooms.com in order
to find spare parts for this product.
5. Place the valve into the tap body and tighten fully using a
suitable spanner.
6. Re-connect the shroud, handle and all other components.
7. Turn on water supply and check for leaks.
8. Contact our helpline should the problem persist.
Valve
Shroud
Screw &
Washer
Indice