The  battery  may  be  damaged  during  the  transportation  process  due  to 

impact or the like. If the battery is found to have any abnormal characteristics, 

such as damage to the battery plastic seal, damage to the outer casing, smell of 

electrolyte gas, electrolyte leakage, etc., the battery shall not be used; 

 

Do  not  use  if  the  battery  emits  odor,  heat, deformation, discoloration  or 

any  other  abnormality;  if  the  battery  is  being  used  or  charged,  immediately 

stop  using  it  from  the  power  off;  if  the  battery  leaks  or  emits  an  odor, 

immediately away from the fire source to avoid fire. Or explosion; 

 

 If  the  electrolyte  leaks  into  the  eyes,  do  not  rub  it,  rinse  with  water  or 

seek medical attention immediately. If left untreated, your eyes will be hurt. 

 Precautions ! 

 

Do  not  use  batteries  in  extremely  hot  environments,  such  as  in  direct 

sunlight  or  in  hot  days.  Otherwise,  the  battery  will  overheat  and  may  catch 

fire (ignition), which will affect the performance of the battery and shorten the 

battery life; 

 

  Use the battery only on the specified device; 

 

   If  the  battery  leaks  and  the  electrolyte  gets  on  the  skin  or  clothing, 

immediately  wash  the  affected  area  with  running  water,  otherwise  it  may 

cause skin irritation; 

 

  Read the battery unit manual to properly install and use the battery; 

 

  If the battery output terminal is dirty, wipe it off with an eraser or a dry 

cloth before use. When the battery is electrically connected to the device, the 

electrical connection point needs to be reliable and firm, and the screw needs 

to be tightened. Otherwise, the contact may be poor, which may cause energy 

loss. In severe cases, it may cause safety problems.

 

Содержание HY48050

Страница 1: ...HY48050 Product User Manual v 20200124 Lithium Iron Phosphate Battery 48V 50Ah Product User Manual...

Страница 2: ...oroughly before using this product Content 1 Overview 2 2 Appearance 2 3 General Structure Description 3 4 List of Accessories 4 5 Electrical Interface 6 6 Technical Specifications 9 7 Battery Single...

Страница 3: ...e shed or workplace such as TVs stereos video games lights fans laptops phones and power tools It can be used on grid and off grid in remote villages districts with inverter and controller and connect...

Страница 4: ...D flashing to show the battery has alarm and lighting to show the battery is under protection RS485 indicator Lighting to show RS485 had connected CAN indicator Lighting to show CAN had connected CAN...

Страница 5: ...emarks 1 48V 50Ah battery module X1 Standard accessories 2 output positive pole line X1 Standard accessories line length 1000mm section 25 mm2 120A max 3 output negative pole line X1 Standard accessor...

Страница 6: ...to the number of battery parallel machines minus one For example when users use two modules in parallel you need to use one 5 parallel positive polar line one 6 parallel negative pole line and one 7...

Страница 7: ...es distributed on the left side of the battery panel which are Power and Power These two interfaces belong to the parallel relationship in the internal and electrical connection of the battery Connect...

Страница 8: ...ata of the battery The CAN matching resistor is required to installed on the device side RS485A and RS485B in the socket can be connected with PC computer and follow the RS485 protocol for battery pac...

Страница 9: ...wn it will be extinguished RS485 Operating Indicator Light white light when battery pack is turned on it will light up after shutdown it will be extinguished ALM alarm light red light when the battery...

Страница 10: ...ns Table 6 Product Specifications LED1 LED2 LED3 LED4 SOC Volume of Battery Pack 25 50 75 100 represents LED lighting represents LED extinguishing Basic Parameters 48V 50Ah Nominal capacity 50Ah Nomin...

Страница 11: ...1 When the battery is not in use please turn off the battery in time to avoid excessive discharge of the battery which will affect the battery life 2 Please connect the battery pack when the power swi...

Страница 12: ...ut line the lock button on the plug of the output line must be pressed 2 Communication Line Connection The CAN port on the battery panel is connected to the communication interface of the inverter by...

Страница 13: ...on with PCS At the same time battery PACK will detect PCS communication commands 2 Start up failure a Communication failure When the battery PACK does not receive the PCS communication command within...

Страница 14: ...mended discharge current is limited to 25A 2 Before parallel connection of the battery pack please measure the output voltage of each batteries Parallel operation is prohibited if the voltage differen...

Страница 15: ...l be connected in parallel using the 7 parallel communication line to connect the communication port of one of the battery to the next adjacent group of battery port and the communication ports of all...

Страница 16: ...and negative ports of a group of battery modules are connected to the inverters by using 2 output positive pole line and 3 output negative pole line The wiring method is detailed in 48V 50Ah parallel...

Страница 17: ...fied in this user manual 2 The charging temperature must not exceed the charging temperature range specified in this user manual 3 It is forbidden to charge the battery for a long time It is forbidden...

Страница 18: ...hould be protected from severe vibration shock or extrusion to prevent sun and rain It should be applied to cars trains ships and airplanes Wait for ordinary transportation 12 Warnings and Precautions...

Страница 19: ...or subject the battery to mechanical shocks Do not short circuit the positive and negative terminals of the battery with wires or other metal objects Do not transport or store the battery with neckla...

Страница 20: ...If left untreated your eyes will be hurt Precautions Do not use batteries in extremely hot environments such as in direct sunlight or in hot days Otherwise the battery will overheat and may catch fir...

Страница 21: ...ologyCo Ltd 20 13 Safety tools Equipment placement conditions 1 Place location must be dry 2 Place location must beflat 3 Keep away from flammable and explosive materials 4 Place location must be with...

Страница 22: ...TECHNOLOGY CO LTD Address No 1 Guliao Second Road Tangxia Town Dongguan City Guangdong Province China Tel 0769 82999888 Fax 0769 82996222 Brand website www herewin com Please visit www herewin com to...

Отзывы: