User manual // Charging Unit Premium
8
HENSEL-VISIT GmbH & Co. KG
3 Safety hints
Please read and comply with the enclosed safety advices and the
instruction manual before operating the system.
The Battery Charger should only be operated in dry rooms. The
item should never be exposed to dripping or splashing water.
Please avoid any damage or bending of the cables. In case of
any damage please immediately contact our service depart-
ment.
Caution! The Battery Charger has a high inner active mains
voltage. Therefore, the authorized Hensel customer service
department must only perform opening of the housing and any
kind of repairs.
The Battery Charger should only be operated on a mains circuit
with earthed connection.
The Battery Charger is exclusively made for the use with the
Porty item. Therefore, no other electrical items may be
connected.
4 Technical Data
Compatibility:
Porty Premium (Plus) Power Pack
(code 4952-4955)
Lead gel battery pack drawer
(code 1497)
Lithium battery pack drawer
(code 1494)
Can also be used for:
Porty 1200 B Power Pack
(code 495)
Battery pack 12 V / 7 Ah
(code 496)
Battery pack drawer
(code 1496)
Input voltage range:
90 VAC … 260 VAC
Output voltage:
max. 14,4 V
Power output:
max. 2 A / 4 A (switches automatically),
short circuit safety and pole safety
Charging time 2 V / 12 Ah: approx. 3 h
Measurements
in
mm
(l x w x h):
155 x 109 x 48
Weight in g:
680
Code no.:
5671