1-4. REPLACEMENT OF
4. Loosen hex nuts on the adjustable foot (10), move motor,
MANDREL (Continued)
and loosen belt. Remove belt.
5. Using a 5/16" Allen wrench, remove set screw (62) from driven
pulley and remove pulley (53).
6. Turn mandrel shaft (52) until the eccentric (49) and rod end
bearing (46) are accessible.
7. Remove shoulder screw (51) and washers (48-43) and allow rod
end bearing (46) and push rod assembly (44) to fall free.
8. Remove four bolts (5) holding mandrel to mounting bracket and
remove.
9. Remove eccentric (49) and eccentric spacer (57) by moving
eccentric clockwise.
The eccentric has left hand threads. Move the eccentric
clockwise or threads of eccentric could be damaged.
1-5. REPLACEMENT OF
MOTOR
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
1. Remove all equipment from top of unit.
2. Remove top (28) by lifting from unit.
3. Remove two screws (17) from cover plate assembly
(16) and slide assembly out towards the sifter basket.
4. Remove nut (50) from cord clamp (26), and pull cord from clamp.