Service menu - appliance test
36
Service instructions
No.
Basic setting
Standard
value
Range of
adjustment
Explanation
50
Controls the cooking chamber
lamp when closing the
cooking chamber door
0
0-60 seconds
602
Maximum power outage
duration for a warm start
100 s
90 – 600
seconds
Time within which the cooking program will
continue after interruption of the power supply.
607
Ready to Cook active
1
0 = Off
1 = On
When the value is "0", Ready2Cook is
permanently deactivated.
609
Interval for saving the
temperatures in the HACCP
log
120 s
1 – 180
seconds
618
Ready to Cook – Finished
message interval
60 s
0 – 300
seconds
Reminder interval after the Ready2Cook
temperature is reached
624
SES status
1
0 = Off
1 = On
When the value is "0", the SES function is
permanently deactivated.
625
Minimum duration of cooking
program for SES
6 min.
4-6 minutes
If the overall duration of a cooking program is
less than this value, the SES does not run.
655
Limitations for Arabic
0
0 = Off
1 = On
When the value is "1", no cooking programs
for pork are displayed
662
Lock screen active
0
0 = Off
1 = On
Display of Lock Screen menu item
674
Auto-start
0
0 = No auto-
start
1= Direct
favorites
2=Always
Automatic start of a cooking program after
selection from AutoChef / Favorite
678
Scanner button available
1
0 = Hidden
1= Visible
Display of scanner function in the title bar.
695
PIN for operation lock
369
0 – 99999