Service menu - appliance test
34
Service instructions
INFORMATION
In case of changes to the wiring, label or deposit note in the unit.
Overview
Assigning the backup relay
Select the defective relay by means of the roller.
Touch the "OK" field.
Changes saved.
Canceling the selection
Touch the "Back" field.
Relay overview
Relay
Connect
or
No.
Description
Instruction
K1
X10
2
Main contactor Q1
Reconnect the line from X10.2 to X12.5 and to
assign a reserve relay to it.
K1
X11
1
POS A
Reconnect the line from X11.1 to X12.5 and to
assign a reserve relay to it.
K2
X11
2
POS B
Reconnect the line from X11.2 to X12.5 and to
assign a reserve relay to it.
K4
X12
3
Magnetic valve for water vapor
elimination K12
Reconnect the line from X12.3 to X12.5 and to
assign a reserve relay to it.
K5
X12
4
Siphon pump G24
Reconnect the line from X12.4 to X12.5 and to
assign a reserve relay to it.
K6
X12
5
Backup relay K6
Reconnect the line from X12.5 to X12.5 and to
assign a reserve relay to it.
K8
X17
1
Solenoid fresh air M8
Reconnect the line from X17.1 to X12.5 and to
assign a reserve relay to it.
K17
X12
1
Circulating pump G16
Reconnect the line from X12.1 to X12.5 and to
assign a reserve relay to it.
Dismantling and re-
programming
After changing the control board the original state is restored. Thus,
the backup relay is not used unnecessarily.
Establish the original condition of the wiring (from X12. 5 to Xx).
Calling up the "Backup relay" in the Service menu.
Select "OFF" using the roller.
The backup relay is deactivated.
Touch the "OK" field.
Changes saved.
FM06-078A