11.1 Emergency operation
Description
In order to allows limited use in case of error, the appliance has
various emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated,
the controller switches back into regular operation automatically. A
reset is not necessary.
INFORMATION
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
Overview
Fault message displayed
Description
Cooking sensor defective.
The core temperature sensor takes over the
function of the cooking chamber sensor.
Water vapor sensor defective
The software controls the water vapor
elimination. This results in higher water
consumption.
Core temperature sensor defective. Cooking program was
canceled.
Function no longer available.