54
Procedure
Frequency
Lubricate filter pan O-rings.
place Filter Drain Pan O-Rings
Every filter pad change.
Changing of oil.
When oil smokes, foams up violently, or
tastes bad.
Cleaning the vat.
Every change of oil.
Inspect filter pan O-rings.
place Filter Drain Pan O-Rings
Quarterly.
Clean blower and vents.
Semi-annually.
3
3..2
20
0 C
Clle
ea
an
n B
Bllo
ow
we
err &
& V
Ve
en
nttss
To ensure proper burner operation, clean the blowers and blower vents twice a year.
1
1))
Press the main power switch to the off position.
2
2))
Unplug power cord and turn gas shut-off handle clockwise to turn off the gas,
and then disconnect the gas line.
3
3))
Disconnect cable restraint and then carefully roll the fryer from the hood far
enough to get behind the fryer.
B
BU
UR
RN
N R
RIIS
SK
K
•
T
To
o a
avvo
oiid
d b
bu
urrn
nss,, u
usse
e cca
arre
e w
wh
he
en
n m
mo
ovviin
ng
g tth
he
e
ffrryye
err tto
o p
prre
evve
en
ntt h
ho
ott cco
oo
okkiin
ng
g o
oiill ffrro
om
m
ssp
plla
assh
hiin
ng
g..
4
4))
Using a cloth or paper towel, clean the blower intake slots to ensure sufficient air
flow to the blowers.
5
5))
Using a Phillip’s-Head screwdriver, remove lower, rear panel.
Содержание EEG-16X
Страница 2: ......
Страница 10: ...Preface viii...
Страница 12: ...Introduction 2...
Страница 22: ...Installation 12 Figure 2 3 2 Well Dimensions Figure 2 4 3 Well Dimensions...
Страница 23: ...Installation 13 Figure 2 5 4 Well Dimensions...
Страница 24: ...Installation 14...
Страница 66: ...Operation 56...
Страница 72: ...Information Mode 62...
Страница 76: ...Product Program Mode 66...
Страница 92: ...Troubleshooting 82...
Страница 93: ...blank page...