Model CFE-415, 427
53
March 2015
“E-25”
Wrong or faulty elements or
wiring problem
Have electrical supply, wiring, and elements checked
Because of the seriousness of this error code, turn the
POWER switch off and back on to cancel
“E-26”
“HEAT AMPS ARE
LOCKED ON”
Faulty contactors or PCB
Have the contactors and PC board checked
This error code could be displayed even with the
POWER switch turned off. Unplug fryer or shut-off
the wall circuit breaker to disconnect electrical power
to fryer.
“E-27”
HEAT AMPS WERE
TOO LOW
Faulty contactors, PCB, or in-
coming power.
Have the contactors, current sensors, PCB, incoming
wiring, and electrical supply checked.
“E-28”
AMP SENSORS NOT
DETECTED
Current sensor board not con-
nected.
Have current transducer wiring and sensors checked.
“E-29”
SHUNT BREAKER
TRIPPED
CALL FOR SERVICE
Shunt circuit breaker tripped.
Have circuit breaker and contactors checked. Service
Tech must enter a code and physically reset the shunt
device to clear the error.
“E-41”, “E-46”
Programming failure
Press power button to frypot off and back on again, if
any of the error codes, have the controls re-initialized;
if error code persists, have the control board replaced
“E-47”
•
Analog converter chip or 12
volt
•
Amp sensor in backwards
•
Faulty PCB
•
Press power button to vat off and back on again, if
“E-47” persists; if the and
DO NOT light-
up when the 8888’s are displayed, have I/O board
replaced
•
Have positions of amp sensors checked
•
Have control panel replaced
“E-48”
Input system error
Have PC board replaced
DISPLAY
CAUSE
CORRECTION
5-3
WARNINGS AND
ERROR MESSAGES
(CONT.)
Содержание CFE-415