Problem

Cause  

Correction

LID/PRESSURE SECTION (Continued)

• Safety relief valve leaking.

• Check and replace if
  necessary per maintenance
  section on the relief valve.

• Pressure pad broken or crushed.

• Replace pressure pads.

Lid won’t move

• Cable on Counterweight

• Put cable on Counterweight

up or down

  loose or broken

  per section on

  Counterweight Cable.

• Check operation of 

• Make proper adjustments.

  counterweight carriage in
  rear of cooker.

HEATING OF SHORTENING SECTION

Shortening will

• Blown fuse or tripped 

• Reset breaker or replace

not heat 

  circuit breaker at supply

   fuse.

  box or control panel.

• Blown fuse at control panel.

• Check fuse per Main-
   tenance Section on fuses

• Faulty Cook/Pump switch.

• Check Cook/Pump switch
   per Maintenance Section on
   Cook/Pump switch.

• Faulty Cord and Plug.

• Check cord and plug and
   power at wall receptacle.

• Faulty contactor.

• Check contactor per
   Maintenance Section on
   contactors.

• Faulty Drain Switch.

• Check drain switch per
   Maintenance Section on
   Drain Switches.

• Faulty PC board.

• Remove and replace control
   panel.

• Faulty high limit control

• Check high limit control

  switch.

   switch per Maintenance
   Section on High Limits.

   

4-8

                              1201

Содержание 581

Страница 1: ... this manual To isolate a malfunction proceed as follows 1 Clearly define the problem or symptom and when it occurs 2 Locate the problem in the Troubleshooting table 3 Review all possible causes Then one at a time work through the list of corrections until the problem is solved 4 Refer to the maintenance procedures in the Maintenance Section to safely and properly make the checkout and repair need...

Страница 2: ...section on programming Remove and replace defec tive probe Change shortening Filter shortening Change shortening Bread product closer to actual frying period Be sure to select the correct product to be cooked e Check temperature setting a Remove and replace defec tive probe Allow proper preheat time Refer to heating elements in the maintenance section Be sure to select the correct product to be co...

Страница 3: ...her Check temperature setting Remove and replace defec tive probe 0 Allow proper preheat time Refer to heating elements in the maintenance section Be sure to select the correct amount of product to be cooked e Replace shortening Check temperature setting e Temperature not recovered when product was dropped in cookpot e Remove and replace defec tive probe 0 Reduce cooking load 0 Remove product imme...

Страница 4: ...fresh Breading mixture incorrect for product spice content too low Cooking temperature too high spice flavors lost Reduce cooking time Reduce cooking temperature Cheek pressure gauge reading check for pressure leaks Be sure to select the correct product to be cooked Sift breading after each use Incorrect breading mixture Discard old breading Use breading designed for the desired product Replace sh...

Страница 5: ...ocessing of product black bone Product not thoroughly cooked red bone Incorrect breading procedures Product partially frozen Product breaded too long prior to cooking Improper loading procedure Wrong cook button pushed Replace shortening and follow recommended care and use of shortening Use fresh product Use correct meat cutting procedures Check cooking time Use fresh product Use fresh product Use...

Страница 6: ...lugged in Check the breaker or fuse at supply box Check control panel fuses electric model only Check voltage at wall receptacle Check MAIN POWER switch Replace if defective Check cord and plug Turn unit off and allow fryer to cool to release pressure from cookpot clean all pressure lines exhaust stacks and conden sation tank Check and clean solenoid valve per Maintenance Section on Solenoid Valve...

Страница 7: ... found and corrected Pressure does not Not enough product in fryer Place proper quantity of build or product not fresh fresh product within cookpot to generate steam Metal shipping spacer not Remove shipping spacer removed from dead weight See Unpacking Section Lid open or not latched Close and latch lid Solenoid valve leaking or Check or clean solenoid not closing valve per maintenance section on...

Страница 8: ...ON Shortening will Blown fuse or tripped Reset breaker or replace not heat circuit breaker at supply fuse box or control panel Blown fuse at control panel Check fuse per Main tenance Section on fuses Faulty Cook Pump switch Check Cook Pump switch per Maintenance Section on Cook Pump switch Faulty Cord and Plug Check cord and plug and power at wall receptacle Faulty contactor Check contactor per Ma...

Страница 9: ...lement s per Maintenance Section on Heating Elements Check contactor per Maintenance Section on Contactors Tighten Replace wire and clean connectors Check temperature setting in the program mode Check faulty contactor per Maintenance Section on Contactors Remove and replace control panel Remove and replace probe Water in shortening Condensation line stopped up Improper or bad shortening Improper f...

Страница 10: ...rain valve will not open by pulling the knob Obstruction in drain Faulty drain valve Filter shortening Clean and neutralize the cookpot Rinse with vinegar to remove the alkaline then rinse with hot water and dry cookpot Only stir on initial heat up Open valve push cleaning brush through drain open ing from inside of cookpot Replace cotter pins in valve coupling Remove obstruction Replace drain val...

Страница 11: ... Control operative all lights on no heat or pressure primary contactor does NOT engage Control operative all lights on has pressure no heat Control operative all lights on heat on no pressure pressure light OFF Control operative all lights on heat on no pressure pressure light ON Check to see if unit has voltage Check fuses Defective power switch SCheck voltage on pins 1 and 7on the power connecto...

Страница 12: ...eads normal defective thermal sensor replace Defective thermal sensor Replace thermal sensor Reset manual high limit thermostat Depress timer switch Control must be completely reprogrammed If the power connector is making poor contact onto the board an error message could be read or it might disable other components When removing connector look down into power connector to see if the ramp connecto...

Отзывы: