Henny Penny
Model 581
Problem
Cause
Correction
LID/PRESSURE SECTION (Continued)
•
Exhaust line to stack clogged
• Clean exhaust line to stack.
DO NOT OPERATE UNIT
IF HIGH PRESSURE
CONDITIONS EXIST,
SEVERE INJURIES AND
BURNS WILL RESULT.
Place the Power/Pump
switch in the “OFF”
position immediately. Release
the pressure by allowing unit
to cool. The pressure will
then drop. Do not resume use
of unit until cause of high
pressure has been found
and corrected.
Pressure does not
• Not enough product in fryer
• Place proper quantity of
build
or product not fresh.
fresh product within
cookpot to generate steam.
• Metal shipping spacer not
• Remove shipping spacer.
removed from dead weight.
See Unpacking Section.
• Lid open or not latched.
• Close and latch lid.
• Solenoid valve leaking or
• Check or clean solenoid
not closing.
valve per maintenance
section on the solenoid
valve.
• Dead weight valve leaking.
• Repair per maintenance sec-
tion on operating valve.
• Pressure not programmed.
• Check programming.
• Lid gasket leaking.
• Reverse gasket or lid needs
adjusted. See Sections 5-10
& 5-13.
1201
4-7