Henning GmbH & Co. KG
page 13
19/02/2019
6.D Choosing Suspension Type
In this menu section one can enter the suspension ratio of the elevator at which you want to
carry out measurements. The ratio is displayed on the main display; however, it is not per-
manently stored in the evaluation unit. After a restart the evaluation unit will automatically
be displaying a suspension of 1 : 1.
By means of the suspension ratio the displayed total weight is calculated. The suspension
ratio has no influence on the individual rope loads.
6.E Saving Data
By touching
the key „save“, a selection menu opens, in which one can choose between the
options “save current weight distribution” and “measurement of load curve”, if you have pur-
chased the optional software “curve storage”. If not, the unit switches automatically to the
allocation of the project-ID (see also 6.E.3).
6.E.1 Save actual sensor result-snapshot
As soon as this key is activated, the data of all connected rope load sensors is evaluated;
the sensor- and load-data is being saved in the evaluation unit. One can allocate a project-
ID at this point (see also 6.E.3). Reports can be issued via the PC-software.
Cancel
Save actual sensor result-
snapshot
Sample load data
continously