Service Manual — COATS Models 950/950 ProRacer/1025/1050/1055 • 9
Is the test wheel balanced
to 0.00 +.02oz?
Are there burrs, dirt, and/or
grease on faceplate, test wheel,
cones, or pressure cup prevent-
ing perfect centering of the
wheel?
Are there worn or defective
cones, pressure cup, threaded
stud, backcone spring, or hub
nut?
Fine balance test wheel
and test again.
Perform WEIGHT “SENSOR CALIBRA-
TION procedure or refer to “ACCURACY
PROBLEMS” flow chart and test again.
Remove burrs and dirt
and test again.
Replace defective parts
and test again.
Yes
Did the balancer pass the
ACCURACY CHECK?
Yes
Yes
No
No
No
No
Yes
Using a dial indicator check the
runout on the mounting surface of the
motor face plate & the runout of the
arbor shaft. Are both total indicated
runouts greater than .001"?
Yes
Try mounting the wheel with a new
centering cone and spring. Does the
balancer now pass the rotational test?
No
No
Yes
Return to FUNCTIONAL
CHECKS.
Replace drive motor, see
Test again.
Rotational Problems (Contactor & Motor Controller Model)
Direct Drive
Содержание COATS 1025
Страница 2: ...ii Service Manual COATS Models 950 950 ProRacer 1025 1050 1055 Direct Drive ...
Страница 33: ...Service Manual COATS Models 950 950 ProRacer 1025 1050 1055 29 Direct Drive 950 Pro Racer Wiring Diagram ...
Страница 34: ...30 Service Manual COATS Models 950 950 ProRacer 1025 1050 1055 Direct Drive 950 Wiring Diagram Contactor Style ...
Страница 37: ...Service Manual COATS Models 950 950 ProRacer 1025 1050 1055 33 Direct Drive Mechanical Hood Switch Diagram ...
Страница 39: ...Service Manual COATS Models 950 950 ProRacer 1025 1050 1055 35 Direct Drive ...
Страница 41: ...Service Manual COATS Models 950 950 ProRacer 1025 1050 1055 37 Direct Drive ...
Страница 48: ...9111123 03 11 05 Copyright 1992 Hennessy Industries and COATS All Rights Reserved Printed in USA ...