8 | www.henleystoves.com
Height Over Roof
Outlet of a chimney or a flue to be not less that 1m above the highest point of contact of chimney and roof. Where the roof has a pitch of
more than 10º on both sides and the outlet is at the ridge or within 600mm of it, the height of the chimney or flue pipe may be reduced to
600mm.
The outlet of a chimney or flue pipe should also be not less than 1m above the top of any opening skylight, opening window or wall
ventilator within 2.3m
Height Over Openings
Each installation is unique to the property so it is not possible to give details to suit every setting. The installation
must comply with Building Regulations and be made using best practice construction methods. Many fireplace
openings have a supporting lintel. Do not remove without supporting the remaining structure of the building. do
not support the structure with the appliance or the flue system.
Take care when installing the appliance. Careless handling and use of tools can damage the finish and/or area.
Choose top or rear flue exit and fit flue collar to suit installation. Seal with fire cement.
Flue Options