Страница 1: ...This product must be installed by a suitably qualified installer PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY For safety reasons it is essential that your stove is correctly installed and operated He...
Страница 2: ...ons Diagram The Clean Air Act 1993 And Smoke Control Areas Combustible Materials Recommended Fuels Lighting The Stove Re fuelling Refuelling On To A Low Fire Bed Fuel overloading Operation With Door L...
Страница 3: ...0 Drawing Height 620mm Width 758mm Depth 370mm Flue Dimentions 153mm Backbox Height 550mm Backbox Width 690mm Henley Stoves All dimensions are correct at time of printing but may be subject to slight...
Страница 4: ...ompleted and signed Name Address Phone Date installed Model Description Serial number Company name Address Phone Stove correctly flued according to building regulations Flue swept and integrity of flu...
Страница 5: ...ds must not be placed in the same room or space as this can cause the appliance to emit fumes into the room 8 Do not obstruct inside or outside ventilation required for the safe use of this appliance...
Страница 6: ...mneys and connecting flue pipe system must meet the requirements of the Building Regulations A flexible flue liner system can be used if certified for use with solid fuel systems and installation comp...
Страница 7: ...dge B Elsewhere on the roof whether pitched or flat At least 2300mm horizontally from the nearest point on the weath er surface a at least 100mm above the highest point of interaction of the chimney a...
Страница 8: ...ylight opening window or wall ventilator within 2 3m Height Over Openings Each installation is unique to the property so it is not possible to give details to suit every setting The installation must...
Страница 9: ...m top of stove External Air Supply If not using External Air Supply do not remove cover from back of outlet The stove can then be fluedl ike a standard stove If not using External Air Supply do not re...
Страница 10: ...ra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act...
Страница 11: ...Note If the flames disappear and there are still lumps of solid wood left this indicates excessive moisture in the wood or insufficient air supply flue draught Note To eliminate unwanted smoke emissio...
Страница 12: ...t the chimney size and type As with all appliances regular sweeping of the flue is essential to avoid the danger of a blockage and escape of poisonous fumes Access for cleaning should be incorporated...
Страница 13: ...ive following the instructions on the bottle Press the rope gasketing into the channel on the rear door casting following the same layout as the old rope seal Just before the final end cut the rope se...
Страница 14: ...Wear suitable gloves for this procedure Take note of the position and joint of the rope gasket Replace the rope gasket remove the self adhesive backing on the rope as you go start at the bottom of the...
Страница 15: ...om Occasional fumes from de ashing and refuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist Open doors and windows to ventilat...
Страница 16: ...ur warranty online or via the post in order to activate the warranty for your stove The appliance needs to be installed by a HETAS approved engineer and in accordance of Building Regulations to be val...
Страница 17: ...ig your spare parts ONLY USE GENUINE HENLEY APPROVED REPLACEMENT PARTS FOR YOUR STOVE Carbon Monoxide Alarm As part of act SI 9 and TGD Part L 2014 it is now mandatory to install a Carbon monoxide dec...
Страница 18: ...up of any moisture inside Seansonal Use A fireguard conforming to BS 8423 2010 should be used in the presence of children the old or infirm Please note this appliance should be used with the fire doo...
Страница 19: ...chimney 3 A simple test would be to open the door of the stove when it is not lighting and listen to see if you can hear wind in the chimney If so this means you will need to install a damper in the...
Страница 20: ......
Страница 21: ...ing from the use of fuel not recommended in the manual Parts which are damaged by external causes such as unadopted chimneys thunderstorms dampness faulty plumbing faulty fuel and mistreatment Specifi...
Страница 22: ...Henley Stoves Henley Stoves Curraheen Tralee Co Kerry Ireland Tel 066 7119788 Fax 066 7124200 Email info henleystoves com www henleystoves com The Heating Specialists Every Home Deserves A Henley...