Technical Bulletin -  OSI Foam Applicator Gun 

– 20171003                                                                                                           Page 

2

 of 

3

 

 

TROUBLESHOOTING 

PROBLEM:

 No product extrudes from the gun applicator when trigger is pulled, or product extrudes too slowly. 

POSSIBLE CAUSE 

SOLUTION 

  Cured product at the tip of the gun can partially or completely block the 

flow of the product 

  Rub the gun tip on a piece of soft lumber, or use a knife, wire brush, 

etc. to remove cured residue. 

  Product is too cold. This will thicken the liquid in the can and reduce 

the propellant pressure, resulting in a slower flow rate 

  It is recommended to store the cans between 65-75°F (18-24°C) prior 

to use. Maintain chemical temperature above 40°F (5°C) for best flow 
rate. DO NOT heat cans with local heat sources (stove, radiators, hot 
plates, etc.)

 

  Basket adapter may become clogged with cured foam product if gun is 

stored without can attached, or if it not cleaned thoroughly when 
changing cans. 

  Foam gun may no longer be useable and needs to be replaced. 

  Slow flow towards end of can may indicate a loss of propellant 

pressure due to either cold temperatures or from dispensing foam 
horizontally. 

  Keep can vertical as possible during dispensing, with valve down. If 

“spitting” or gas lose is excessive, shake can periodically as the can 
empties. 

  Regulating screw on back of gun is in closed position. 

  Open regulating screw on back of gun by turning counterclockwise  

  Product is past its shelf Life 

  Shake can. If no liquid movement is felt (or product is very thick) then 

it may be past its shelf life and needs to be replaced 

  Product does not dispense after storage. 

  Product was stored beyond 30 days after original opening, or product 

has expired shelf life. 

  PU foam leaks out of gun when it is off: 

  Remove the canister, release the pressure and empty the foam 

remaining in the applicator.  Clean gun then remove and clean the 
needle with OSI® Foam Cleaner (see above steps 5 and 6). If the gun 
continues to leak the parts may be worn and the gun needs to be 
replaced. 

 

PROBLEM:

 trigger will not depress 

POSSIBLE CAUSE 

SOLUTION 

  Regulating screw on back of gun is in closed position. 

  Open regulating screw on back of gun by turning counter-clockwise  

  Cured product on needle valve may cause the trigger to stick. 

Excessive force should not be used if trigger will not open readily, as 
this may cause damage to parts 

  If the needle valve cannot be dislodged using the trigger, it may be 

able to be “broken free” by turning or carefully removing the regulator 
screw being careful not to lose the spring and ball. Turn the needle 
valve using a set of pliers. If this does not free the valve, then the 
internal parts are clogged with cured foam and the gun needs to be 
replaced.

 

 

PROBLEM:

 Properties of dispensed product not acceptable or behaving unusually 

POSSIBLE CAUSE 

SOLUTION 

 

“Spitting” during dispensing or propellant bursts can be caused by not 
keeping can vertical with valve down. 

  Slight spitting can be expected. Excessive spitting is not normal. Keep 

can vertical with valve down. Intermittent shaking of can is required to 
keep the contents mixed properly. Aerosol cans must be shaken 
during and in between work interruptions. 

  Cured product on needle valve may cause the trigger to stick. 

Excessive force should not be used if trigger will not open readily, as 
this may cause damage to parts 

  If the needle valve cannot be dislodged using the trigger, it may be 

able to be “broken free” by turning or carefully removing the regulator 
screw being careful not to lose the spring and ball. Turn the needle 
valve using a set of pliers. If this does not free the valve, then the 
internal parts are clogged with cured foam and the gun needs to be 
replaced.

 

  The appearance of the dispensed bead of foam can be greatly 

affected by the condition of the dispensing gun. Larger open celled 
appearance may result if gun is not properly maintained. Also, product 
that is left in the barrel of the gun, or allowed to get too cold may also 
affect appearance. 

  The initial burst of material from the barrel may be more open celled 

than normal. If unacceptable appearance continues, then the basket 
adapter may need a thorough cleaning. Test with a fresh can or 
product that is at the proper dispensing temperature for dispensing. 

 