6.3 Entering/Editing a Program
1. Turn the “POWER” on (the position marked “|”). The rocker switch should light up green when the
power is on. The rotary dispense system automatically defaults to the auto mode. For more
information on the auto mode, please see section 5.2.2.
2. Change the mode to set up mode by pressing the mode button. See section 5.2.1 for detailed
instructions on changing modes and section 5.2.3 for more information on the set up mode.
Warning!
When changing modes, the slide with valve/syringe may automatically retract.
3. Note all the start and end positions in degrees for the arcs, circles and/or dots in the program.
The current position is displayed in the top right hand corner of the display to the nearest
tenth of a degree. Use the “Up/Dn” button to advance or retract the slide. Advance the slide
to record the current position and retract it to clear obstructions. Using the “Left” and
“Right” buttons move the rotary table clockwise and counter clockwise, respectively.
4. Once all points have been noted, use the mode button to change to program mode. Please
refer to section 5.2.4 for more detailed information on program mode.
5. Select the desired program number (1-10) using the up and down arrows then select “Next”.
6. Enter the number of events in the program (1-8) using the up and down arrows then select
“Next”. An “event” is a circle, arc or points.
25