11. Enter the Timer B (0 to 9.99 seconds) for Event #1 using the up and down arrows then select
“Next”. The definition for Timer B varies depending on the dispense pattern. For a circle or arc,
Timer B indicates the amount of time before the dispense tip reaches End Position 1 that the
dispenser will shut off. This can be used to shut the dispenser off early so that excess adhesive
that flows after the dispenser is turned off does not cause stringing. When dispensing dots,
Timer B equals the dispense time for the dot.
12. Enter the rotating speed (0.2 to 100 rpm) for Event #1 using the up and down arrows then
select “Next”.
Notice:
When dispensing a dot, there is no rotation within the event, hence, this value is
not used.
13. Repeat steps 8-12 for each event in the program.
28