5.2.1 Event Specific Parameters
The five event specific parameters are detailed below. Please refer to the sample programs in
Section 6.4 for function diagrams that also graphically demonstrate these definitions.
Program
Specific
Parameter
Default
Value
(Event 1)
Range
Description
Start Pos
0.0 deg
0-890.0 deg
The start position in degrees for an event. The station will
normally be programmed to rotate clockwise when dispensing so
that the degree position will increase from start position to the
end position. It should be noted that it is possible to rotate
clockwise, counter-clockwise or both within a given program.
Timer A
0.5 sec
0-9.9 sec
Circles and arcs:
The amount of time after the rotary dispense station arrives at the
start location for that event before the station will start rotating at
the specified event speed. This can be used to add a delay in the
dispense program that will allow the adhesive to start flowing
from the dispense tip before the station starts turning. It could
also be used to put a large dot of adhesive at the beginning of the
arc or circle event. This normally needs to be equal to or slightly
longer than the global dispense delay.
Dots:
The time that the slide will be given a signal to advanced. Since
it takes some time for the slide to advance, typically about 0.5
seconds, the actual time advanced will be shorter than Timer A.
End Pos
360.0 deg
0-890.0 deg
The end position in degrees for an event. When dot dispensing,
the end position must exactly equal the start position.
Timer B
0.25 sec
0-9.9 sec
Circles and arcs:
The amount of time before the dispense tip reaches the end
positions that the dispenser will shut off. This can be used to
shut the dispenser off early so that excess adhesive that flows
after the dispenser is turned off due to residual pressure in the
dispense tip does not cause stringing.
Dots:
The dispense time for the dot.
Rpm
10.0 rpm
0-99.9 sec
The rotating speed for the event. The speed for each arc and
circle can vary resulting in different beads being dispensed for
each event. This parameter is not used when dispensing dots.
5.3 Resetting All Global and Program Parameters to Factory Defaults
To reset the global and program parameters to the factory default settings:
1. Enter the program mode (refer to section 6.2.5 for detailed instructions).
2. Press the mode button for 2 seconds to enter the global parameters mode (refer to section
6.2.7)
3. Hold both the up and down arrow at the same time for 5 seconds or until you see the
following message appear on the display screen, “All program and global parameters
reset”.
Once this message appears you are automatically put into auto mode.