7
4.
The
Loctite® EQ VA40 CA Volumetric Valve
is ready to dispense. Set actuation rate at
greater than or equal to 0.2 seconds.
5.
Cycle the
Loctite® EQ VA40 CA Volumetric Valve
5 -10 times and then measure drop
size. Adjust stroke to suit.
6
Application Hints
The Loctite
®
EQ VA40 is specifically designed to dispense drops of
Loctite®
Cyanoacrylate Adhesive. This adhesive is moisture sensitive. Clean dry air must be
used to pressurize adhesive but for best results dry nitrogen is recommended.
Shutdown
–
Always keep the
Loctite® EQ VA40 CA Volumetric Valve full of adhesive.
At the end of the day depressurize the reservoir. The dispense needle will cure and seal
the system. Always install a new dispense tip after all extended shutdown periods.
7
Troubleshooting
Problem
Possible Cause
Correction
No liquid flow
•
If pneumatic valve
operating pressure is to
low, the valve will not shift.
•
The reservoir pressure may
not be high enough
•
Displacement rod may be
in forward position
•
The dispense tip may be
clogged.
•
Stroke Adjuster maybe out
of range
•
Increase air pressure to 60
psi (4 bar) minimum
•
Increase pressure to 30 psi
(2 bar)
•
Check air lines to ensure
that the normally open
airport is energized
•
Replace tip
•
Ensure stroke adjuster is
with 2.25 revolutions of
adjustment. (section 5-3)