background image

 

   

- 1  -

1

INTRODUCTION

--- 

        Thank your for your purchase of a Hengx high resolution electronic scale. This scale enables you to measure the 
quality and weight. The scale is easy to operate, precise, stable and with fast display reaction. It is applicable in the 
electronic, hardware, plastic, medicine, textile and various other industries. It is useful for packaging, inventory and 
various production and quality control cases. 

2

ASSEMBLY

--- 

3

INSTALLATION

--- 

z

 Assembly

please follow the sequence

 

z

  Release and remove the protection screw

6

to resist the bottom housing

 

z

  Always lock the protection screw before transportation 

z

 

1

Power switch 

z

 

2

RS-232 uni-direction 

z

 

3

RS-232 bi-direction 

z

 

4

DC power connector 

z

 

5

RELAY check-weighing (output) 

 

4

PRECAUTION

--- 

1

  full charge the battery after unpacking the scale. 

2

  recharge the battery: when battery symbol appears on the LCD display, please plug in the power lord to charge the 

battery. The indicator of charge will light up in red. When it becomes green means charge completed( it takes about 
8hours to full recharge the battery)*.

 

3

  install the equipment on a level and stable surface. 

4

  do not install the equipment near the air condition or a vibrating machine. 

5

  Please in the temperature of 0 ~ 40

prevent from rapid temperature changes. 

6

  independent AC outlet for this equipment is recommended, check the voltage before plug in. 

7

  warm up the equipment for 15 minutes before use.

 

Содержание 1530

Страница 1: ...ING 7 UNITS SETTING 7 INITIAL UNIT SETTING 8 8 KEYPAD 8 ZERO 8 TARE 8 PRE TARE 9 0 9 AND 9 IMPUT ELIMINATE 9 WEIGHING FUNCTION CONVERSION 10 UNITS CONVERSION 10 SAMPLE IN PCS AND MODE 10 PRINT 10 RETURN 10 NET AND TOTAL WEIGHT CONVERSION 10 ACCUMULATE 11 ACCUMULATE DISPLAY 12 ACCUMULATION ELIMINATE 13 CHECK WEIGHING 14 AUTO TARE 14 9 CALIBRATION OPERATION 15 9 1 CALIBRATION six point calibration 1...

Страница 2: ...ion z 1 Power switch z 2 RS 232 uni direction z 3 RS 232 bi direction z 4 DC power connector z 5 RELAY check weighing output 4 PRECAUTION 1 full charge the battery after unpacking the scale 2 recharge the battery when battery symbol appears on the LCD display please plug in the power lord to charge the battery The indicator of charge will light up in red When it becomes green means charge complete...

Страница 3: ... accumulation value print H BACKLIGHT AUTO ON I 2 sets of RS 232 option J Relay output option K Mini printer option L RTC option 3 clear LCD display with 22mm digits 4 backlight function 5 over load and transportation protection 6 membrane keypad easy operation and nice water resistant function 7 can be used as simple counting scale 8 stainless steel weighing pan 6 AVAILABLE UNITS 1 1 kg 1000g 2 1...

Страница 4: ...Weighing mode conversion 5 When some weight on the pan Press tare to tare 1 2 Net weight total weight conversion 6 For pre tare used to check in accumulation display and eliminate 1 3 Return 7 Put samples onto the pan and input the number then press sample 1 4 Press to enter weight quantity and HI LO OK check weighing setting 1 5 Used for inputting number data Panel illuminate 1 6 Display weight 1...

Страница 5: ...re initial setting OPERATION LCD display press to switch on Backlight setting press z on off auto on means the backlight is always be light off means the backlight is turn down auto means the backlight will on when there is weight on it press to change the setting Resolution setting press z 1 15000 dual display resolution 2 3000 or 3750 3 6000 or 7500 4 15000 normal type z 2 3000 or 3750 3 6000 or...

Страница 6: ...ade press to select in turn Zero band setting press z d0 d1 d2 d3 d4 d5 more bigger means auto zero Tracking more bigger press to select in turn Band rate setting press z band rate setting 9600 Buzzer setting press z on buzzer on oFF buzzer off press to select in turn ...

Страница 7: ...upper than 3kg and lower than 1kg then you choose Un if you want it warning just in 3kg 2kg and 1kg then you choose 3b if you want it warning in 2kg then you choose OK if you do want any warning then you choose OFF press to select in turn Check weighing memory setting press z M On M oFF M On means check weighing memory is open M oFF means check weighing memory is closed press to select in turn pre...

Страница 8: ...en press to select in turn Auto tare setting press z YES on NO off press to select in turn RS232 output content setting net weight press z Pr print nP not print press to select in turn RS232 output content setting accumulation value press z Pr print nP not print press to select in turn Units setting press then press press and on off setting in turn press back to parameter setting ...

Страница 9: ... 8 Initial unit setting press z units press to select in turn press back to normal weighing mode 8 KEYPAD ZERO z press tare z z press z tare can t operate below zero or above max capacity ...

Страница 10: ...ss z press and to input pre tare value z press z tare condition zero symbol should display on 0 9 and z and z to load the pre tare value and check weighing Imput eliminate z press z in the pre tare check weighing mode ...

Страница 11: ...ess z for units conversion Sample in PCS and mode z in PCS and mode z press and z put on object z press to sample print Condition of printing must be stable press printing LCD display value return press return to weighing mode Net and total weight conversion press net and total weight conversion ...

Страница 12: ...iton only can accumulate once remove objects on the pan and could accumulate once more totally can accumulate for ten times z 1 sec later return to normal weighing mode z when accumulating more than 10 times z means times of accumulation over range 1sec later return to normal weighing mode ...

Страница 13: ...eans accumulate the first accumulation and quantities of individual accumulation z press z means total weight accumulation times of accumulation and quantities of accumulation z press back to normal weighing mode z when total value of accumulation over display range it will show press to get the accumulation value ...

Страница 14: ...ation z press z means accumulate value of the first time and individual quantities z press to cancel the accumulation value z press z means total weight times and quantities of accumulation z press to cancel the accumulation value z press back to normal weighing mode z press to get accumulation value ...

Страница 15: ...ress back to normal weighing mode when check weighing wrong it will show z press to cancel check weighing and back to normal weighing mode Auto tare z auto tare condition cann t work below zero or above max capacity In the stable condition max 2 z Can not tare constantly after auto tare press tare to cancel pre tare and get new tare value z if need another auto tare clear the pan press zero or tar...

Страница 16: ...ne z press z zero point calibration z waiting z place 1 6 of load on press to perform 1 6 load calibration z waiting z place 2 6 of load on press to perform 2 6 load calibration z waiting z place 3 6 of load on press to perform 3 6 load calibration z waiting z place 4 6 of load on press to perform 4 6 load calibration ...

Страница 17: ...calibration z waiting z place full load on press to perform full load calibration z waiting z press to return normal weighing mode 9 2 single point calibration operation LCD display z press to switch on the machine z press z press z place poise of equivalent weight ...

Страница 18: ... z press z press back to normal weighing mode 10 COUNT DISPLAY testing operation LCD display z press to switch on the machine z press z then press any other key display total weight z press display offset value z press back to normal weighing mode ...

Страница 19: ... 18 11 RTC z press to switch on the machine z press z press z press to choose on with RTC oFF without RTC z press z press back to normal weighing mode ...

Страница 20: ... 19 RTC time display operation LCD display z press to switch on the machine z press z press z press to display on turn z press z press back to normal weighing mode ...

Страница 21: ...ime setting operation LCD display z press to switch on the machine z press z press z press to display in turn z press from let to right to load time press to confirm z press z press back to normal weighing mode ...

Страница 22: ...001kg 0 001kg 0 002kg Resolution g 0 1g 0 2g 0 2g 0 5g 0 5g 1g 1g 2g Linearity 2d 2d 2d 2d Repeatability 0 1g 0 2g 0 2g 0 5g 0 5g 1g 1g 2g Internal resolution 0 01g 0 02g 0 05g 0 1 LCD LCD Display LED backlight 6 1 2 Digits With 24 5 mm digits dimension 300X320 cm pan 300X200 cm adaptor DC12V 300mA Adaptor 6V4A rechargeable battery resolution 1 7 500 1 6 000 Keypad 25 key Protect device Over load ...

Страница 23: ...ulation 10 times Pre tare linearity calibration six point 1 6 max 2 6 max 3 6 max 4 6 max 5 6 max max soft ware filtering units conversion printer setting and auto average temperature 0 c 40 c RS 232 Bi direction and dual direction can connect with PC SH 24 TDP 643 printer SCR RELAY HI LO OK RELAY output bi direction RS 232 interface 14 RS 232 output format Remarks for Dual output 1 data can be se...

Страница 24: ...W k g CP LF T W k g CP LF G W k g CP LF e g N W 1 000 kg T W 0 050 kg G W 1 050 kg DATA FORMAT Prt Co N W g CP LF T W g CP LF G W g CP LF e g N W 1000 g T W 50 g G W 1050 g DATA FORMAT Prt Co N W l b CP LF T W l b CP LF G W l b CP LF e g N W 1 000 lb T W 0 050 lb G W 1 050 lb DATA FORMAT Prt Co N W o z CP LF T W o z CP LF G W o z CP LF e g N W 1 000 oz T W 0 050 oz G W 1 050 oz DATA FORMAT Prt Co ...

Страница 25: ... FORMAT Prt Co N W t l H CP LF T W t l H CP LF G W t l H CP LF e g N W 1 000 tl H T W 0 050 tl H G W 1 050 tl H DATA FORMAT Prt Co N W P C S CP LF T W P C S CP LF G W P C S CP LF e g N W 1000 PCS T W 50 PCS G W 1050 PCS DATA FORMAT Prt Co N W CP LF T W CP LF G W CP LF e g N W 1000 T W 50 G W 1050 DATA FORMAT Prt St Prt Pr A c c X X N W X X X X X X CP LF A c c A l l X X N W X X X X X X CP LF e g HA...

Отзывы: