Operating Instructions tico 735 - Elapsed Timer

page 11/12

Technical Data

Display

Primary Display

Red/Green, 7 segment LED, 5 digits, height 18.5 mm

and Keyboard

Secondary Display

Red/Green, single digit 7 segment LED, height 7 mm

Annunciators

1 red LED for OUT1

Keyboard

4 rubber keys for programming and manual reset

Physical

Dimensions

DIN 48 mm x 96 mm, 110 mm total depth

Mounting

Front panel mounting (mounting bracket supplied)

Panel Cutout

45+0.5 mm x 92+0.5 mm, panel thickness max 12 mm

Construction

Front carrier with circuit boards can be pulled out

Terminals

Screw Type - combination head

Environmental

Power Supply

90 - 264 VAC 50/60 Hz (electrically separated from all inputs and outputs) or

20 to 50 VAC / 22 to 55 VDC

Power Consumption

4 Watts

Temperature

Operation:

0°C to +55°C

(32°F to 131°F)

Storage:

-20°C to +80°C

(-4°F to 176°F)

Relative Humidity

20 % to 90 %, non-condensing

Approvals

Ratings

Frontpanel IP 66

EMC Susceptibility

Complies with EN 50082-1/92-95

EMC Emissions

Complies with EN 50081-1/92, -2/94

Safety

DIN EN 61010 part 1; according to protection class II

General

Overvoltage category II, Contamination level 2

UL, CUL

Start Input A

Active Edge

NPN or PNP programmable; capable of TTL; 30 VDC max

when PNP

High

3.0 V, Low < 2.0 V or open; 10 kOhm to 0V

when NPN

High

3.0 V or open, Low < 2.0 V; 4.7 kOhm to V+

Control Inputs

CTRL1

(Reset)

NPN; High

3.0 V or open, Low < 2.0 V; 4,7 kOhm to V+

edge sensitive; 25 ms min., max 30 VDC

CTRL2

(Security Lockout)

NPN; High

3.0 V or open, Low < 2.0 V; 4,7 kOhm to V+

level sensitive; 25 ms min.; max 30 VDC

Outputs

OUT1 NPN

Open Collector; 30 VDC max; 100 mA max;

response time < 75 µs at < 2 µs cyclical accuracy

OUT1 Relay

Changeover (Form C); 240 VAC / 3A or 115 VAC / 5A;

pull-in time approx. 8 ms

Sensor Power Supply

12 (unregulated VDC), 125 mA max; ripple < 0.5 V

RS-485 Option

Type

RS485, serial asynchronous, Open ASCII, Master-Slave, up to 99 zones

Parameters

9600...1200 Bd, 1 start, 7 data, 1 stop, even parity

Содержание tico 735

Страница 1: ...ained The operation mode provides day to day operation and allows editing of preset values The Program Mode enables the configuration of various parameters prior to initial operation These parameters include those for basic configuration as well as other settable features which will enhance the functionality and usability of the device This manual also provides information on the tico 735 Elapsed ...

Страница 2: ...re asked for the device in the pertaining standards for safety are not affected in a negative way so reducing the safety of this mount device Mounting and assembling of device needs observation of the specifications of the local Energy Suppliers Before switching on make sure that the power and control voltages are not exceeding the values in accordance with the technical data If it is to be assume...

Страница 3: ...is not distorted and the instrument is positioned squarely against the panel Slide the mounting clamp into place on the instrument and push it forward until it is firmly in contact with the rear face of the mounting panel and the tabs on the bracket arm are seated in the mounting grooves on the side of the unit The electronic components of the instrument can be removed from the housing after insta...

Страница 4: ...cessed by connecting the positive supply side of the sensor to Terminal 4 and the negative side to Terminal 8 Power Supply Input For an AC powered unit Terminal 13 serves as the line or hot side connection for AC powered units and as the positive side for DC powered units The neutral side for AC powered units and the negative side for DC powered units are connected to terminal 14 Transistor Output...

Страница 5: ... edited parameter values Holding the key down for 3 seconds will cause the unit to return to Operation Mode Reset In Operation Mode Resets the time value to zero This button can be disabled via the Front Panel Reset Enable parameter in Program Mode In Program Mode No function Down Scroll In All Modes Will abort an Edit Operation and return the preset parameter to its previous value Display functio...

Страница 6: ...ost significant digit flashing P Use the Scroll Key to move from left to right and highlight the digit that needs to be changed Wrap around will occur from the least significant to the most significant digit O Use the Down Key to decrement the digit until the desired value appears The display will wrap around from 0 to 9 After the desired digits have been changed press the Program Key to enter the...

Страница 7: ...e To exit Program Mode hold the Program Key for 3 seconds Parameter names will not appear on the main display if the Help function has been disabled in Program Mode 1CN DE 3 secs or Edit Operation R1 Pressing the Scroll Key or no key activity for 3 seconds will display the value for that parameter The secondary display will indicate the one digit identifier for the parameter The digit in the secon...

Страница 8: ...e timed in minutes 1 Hours Input pulses will be timed in hours DE DE Minutes Seconds Input pulses will be timed in minutes hours and seconds minutes Timing Direction Function Determines if the time value will increment from zero and change the state of the output at the set value Up or decrement from the set value and change the state of the output at zero Down Adjustment Range 1 1 Up The unit wil...

Страница 9: ...the default will be Fitted If the board is installed in the field this parameter will need to be changed from its default of none Communication Address Appears only if communication board is installed and activated Function Defines the unique communication address of the counter Adjustment Range 1 to 99 Default Value 1 1 Baud Rate Appears only if communication board is installed and activated Func...

Страница 10: ...t Function Determines whether the multi character parameter name will appear on the main display for 3 seconds prior to the paramter value appearing Adjustment Range 4 4 Help Yes Multi character parameter descriptions will appear on the primary display The value associated with that parameter will appear by pressing the scroll key or waiting for 3 seconds Help No Only the parameter values will app...

Страница 11: ...ity 20 to 90 non condensing Approvals Ratings Frontpanel IP 66 EMC Susceptibility Complies with EN 50082 1 92 95 EMC Emissions Complies with EN 50081 1 92 2 94 Safety DIN EN 61010 part 1 according to protection class II General Overvoltage category II Contamination level 2 UL CUL Start Input A Active Edge NPN or PNP programmable capable of TTL 30 VDC max when PNP High 3 0 V Low 2 0 V or open 10 kO...

Страница 12: ... Tacho Rate Meter 22 55V 5 Rate Totaliser 6 Time Counter Linear Output 7 1 Preset Counter 0 none 8 2 Preset Counter 3 with 4 20 mA 9 Batch Counter only with function 2 4 5 1998 HENGSTLER GmbH This documentation may not be changed amended or copied without prior written consent of HENGSTLER GmbH and may not be used in contradiction to this company s rightful interests Hengstler GmbH Postfach 11 51 ...