14/28
Sach-Nr. 2 732 017; Version 1310301WBI
4.2
Programming of functionscodes
Programming mode:
press while
switching
Power on
Change parameter:
press
Return to count mode:
press
> 5 s e c
Change to the next function:
press
function
code alternatives/signification
basic settings
F0
0*
no function
1
all function codes are set to the *-marked values
time unit
F2
0*
seconds
1
minutes
2
hours
3
format HH.MM.SS
resolution
F3
0*
no decimal point
1
one decimal place (xxxxx.x); 0.1 time unit
2
two decimal places (xxxx.xx); 0.01 time unit
3
three decimal places (xxx.xxx); 0.001 time unit, F 2 = 0, solution in msec
reset/setmode
F4
0*
reset to „0“, no autoreset
1
reset to „0“, with autoreset when reaching preset 2
6
2
set to preset 2
6
, no autoreset
3
set to preset 2
6
, with autoreset when reaching „0“
signal time
F6
1
OFF
no Output signal
output 1
On
bistable Output signal, will be deleted by Out 2
0,02
20 ms
0,05
50 ms
0,10*
100 ms
0,20
200 ms
0,50
500 ms
1,00
1 s
signal time
F7
1
see
see above; signal time output 1
output 2
above
time counter mode
F8
0*
cumulated counting with pulse width measurement
3
1
cumulated counting with period measurement
4
2
single counting
5
with pulse width measurement
3
3
single counting
5
with period measurement
4
Output in case of
F9
0*
Output from main preset (OUT 2)
2
is not activated
reset
by reset
1
Output from main preset (OUT 2)
2
is activated by reset
pnp/npn-
F10
0
npn with 8V level (negative)
selection
1*
pnp with 8V level (positive)
2
npn with TTL-level
3
pnp with TTL-level
input
F11
0
30 Hz attenuation (for contacts)
attentuation
1*
no attentuation, 5 kHz
(bidirectional counting: 2,5 kHz)
dyn./static
F12
0*
static reset
Reset
1
dynamic reset (counting possible during reseting)
output
F14
0*
after power fail, the signal times will not be
signal memory
restarted
1
after power fail, the signal times will be restarted
additional
F15
0*
disabled
totalizer
1
enabled
Stop after main
F16
0*
no stop after main preset reached
preset reached
1
stop after main preset reached
1
irrespective of measurements
keylock for
F20
0*
key reset is possible
reset key 6+4
1
key reset is not possible (or possible with delay
see F29)
keylock for preset 1
F21
1
0*
access to preset 1 is possible
1
access to preset 1 is not possible (or delayed see F29)
keylock for preset 2
F22
1
0*
access to preset 2 is possible
1
access to preset 2 is not possible (or delayed see F29)
keylock mode for
F29
0*
access to parameters from F20-F22 is possible after
(F20-F23)
holding the keys for more than 10 sec.
1
access to parameter is not possible
* default values
1
parameter only appears for preset version
2
with appliances with one preset only, this applies to preset 1 and output 1 (OUT 1)
3
counting as long as Input A is active (see example 1)
4
counting starts and stops with the leading edge (see example 2).
5
with every start signal the counter starts again from zero
New!
New!