3.4.5 Input/output signal wiring
Note
Once a channel input signal is a switching signal, this channel will no longer
support analog, RTD, thermocouple and other signals.
Other signals such as Pt1000, 0-10V, etc. should be specified when
ordering.
3.4.6 Relay contact output wiring
Note
Wiring wire cross-sectional area: 0.5~2.5mm2, torque: 50Nm. The machine
is shipped in normally open mode by default, please specify other modes
when ordering.