15
EN
Troubleshooting
Problem
Cause
Solution
The device does not
regenerate
No power supply
Check electrical connections - fuses, plug,
switch. If necessary, regenerate the device
manually
Improperly programmed controller
Set the controller or contact a professional in
order to set the controller properly
The device delivers hard
water
Lack of salt in the brine tank
Refill salt and regenerate the resin with the
button of immediate regeneration
Contaminated injector
Contact a professional or clean the injector
Insufficient water refill of the brine tank
Check the time of brine tank refill and
regenerate the resin
Pressure drop
Deposits of iron in the softener
Clean the device and resin.
Increase the frequency of regeneration and /
or duration of the back rinse
Clogged water installation
Check if impurities from water did not clog
the water installation upstream the device
Controller’s inlet contaminated with
impurities remaining from installation works
Remove impurities and clean the controller
Contaminated pre-cleaning filter cartridge
Clean the cartridge or replace
Air in the system
Check the installation and verify if brine is
present in the tank
Too much water in the
brine tank
Clogged injector
Clean the injector
Foreign bodies in the brine valve
Replace the brine valve
Power supply interrupted
Check the electrical connections
The device does not suck
the brine
Too low pressure in the water mains
Increase the pressure of water at the inlet to
the water treatment system, to the minimum
of 1.8 bar
Clogged brine supply hose to the controller
Check the brine supply hose and remove any
impurities protruding the flow
Leak from the brine supply hose
Replace the brine supply hose to the
controller
Damaged injector
Replace the injector
Foreign bodies in the valve
Check the inside of the valve, remove any
impurities, check the operation of valve in
different regeneration positions
Constant leak to sewage
Power supply interrupted
during regeneration
Check the electrical connections
Содержание 230442
Страница 54: ...54 PL Schemat cyklu pracy dla modelu 230442 Start Status uzdatniania wody ...
Страница 116: ...116 RU Схема эксплуатационных циклов прибора модели 230442 ...
Страница 117: ...117 RU Схема эксплуатационных циклов прибора модели 230459 Использование Панель управления в модели 230442 ...
Страница 132: ...132 GR διάγραμμα κύκλων λειτουργίας της συσκευής για το μοντέλο 230442 ...
Страница 133: ...133 GR διάγραμμα κύκλων λειτουργίας της συσκευής για το μοντέλο 230459 Χρηση Πινακας ελεγχου στο μοντελο 230442 ...
Страница 142: ...142 ...
Страница 143: ...143 ...