background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

14. Set track stops to limit travel 

Tighten 
once 
position 
set 

13. Fit Door Guide using spirit level 

Adjust door stop if required before 

fixing to ensure door is vertical 

Содержание Evolve Glass SIM Kit

Страница 1: ... specifications must be respected in especially maximum weight restriction of the door leaf Any other use of this product is considered inappropriate use It is not guaranteed that this product will work in combination with fittings motors or other electronic devices supplied by other manufactures The appliance is only to be used with the power supply unit provided Before you commence work please r...

Страница 2: ...ations End elevations Tools required Electricians Screwdriver Posi Head Screwdriver 3 4 5mm Allen keys Scissors Torque Wrench and 6mm bit Electric Drill twist drill Tape Measure Spirit Level 3 10 13mm Spanner ...

Страница 3: ...Installation System layout CLOSED POSITION ...

Страница 4: ...Quick overview Wiring wall mounted socket For detailed operation and programming instructions please consult the separate Evolve Motor and Wiring Fitting Instructions supplied ...

Страница 5: ...Fused Spur Not PCH Motor Unit 24V Transformer Wall mounted control device inputs Transformer input Remote sensor or additional switch input ...

Страница 6: ...is off B Potentiometer Detail Automatic closing delay time To prolong automatic closing delay time Turn potentiometer Clockwise To reduce the automatic closing delay time Turn potentiometer Anti clockwise NOTICE Potentiometer have a right and left stop point which must not be overtightened Adjust potentiometer slightly with an appropriate tool Damage to control device may result in malfunction Qui...

Страница 7: ...ated the lowest speed is set 20 cm s When more than one switches are activated a reduced speed is set 12 cm s Perform Reset Switch power supply on Control device in delivery status or after power cut Red LED blinks continuously twice with a short break of 1 5sec Press RESET for about 2 seconds Red LED blinks continuously Check driving direction of motor with control keys When pressing OPEN door ha...

Страница 8: ...1 Secure motor unit to track by inserting block into track and tightening bolts to clamp over bottom of track Track Connector block Connector Block Spacer Track Motor ...

Страница 9: ...M6x25 Bolts 180mm Offset to accommodate door under motor unit 2 Door and hardware preparation overview 3 Attach glass clamps Panel positioned under motor highlighted ...

Страница 10: ... clamp b Locate second half of glass clamp over knee of first c Secure glass clamp with screws d Attach spacer block with screws to top of clamp e Attach belt clamp with screws on to top of spacer a Position first half of glass clamp b Locate second half of glass clamp over knee of first c Secure glass clamp with screws a b c ...

Страница 11: ...fixing installation spacing between brackets is 600mm MAX Use suitable wall anchors NOT PCH 6 Secure track soffit fix installation spacing between brackets is 600mm MAX Use suitable wall anchors NOT PCH 1 SS bracket Fit suitable wall anchors a d c b e ...

Страница 12: ...Toothed belt Tension wheel arrangement in track 8 Remove covers to allow toothed belt to be attached ...

Страница 13: ...9 Hang glass door 10 Set door height ...

Страница 14: ...oothed belt Push tension wheel assembly so that the belt is torte and secure assembly in position by tightening the M6 grub screw 11 Loosen belt clamp Cut belt to length Tighten to secure belt Tighten to clamp belt ...

Страница 15: ...14 Set track stops to limit travel Tighten once position set 13 Fit Door Guide using spirit level Adjust door stop if required before fixing to ensure door is vertical ...

Страница 16: ...ere is a risk of being crushed cut or dragged and danger areas in general Make sure the existing structure is up to standard in terms of strength and stability Each installation must clearly show the identification details of the motorized door or gate Apply hazard area notices required by applicable regulations The electricity supply must be isolated at tis source before attempting installation o...

Страница 17: ...moving Do not allow children to play or stay within the field of action of the motorised door Keep remote control or any other control devices out of reach of children In order to avoid possible involuntary activation of the motorised door In the case of breakdown or malfunction of the product disconnect form the mains do not attempt to repair or intervene directly contact only qualified personnel...

Страница 18: ......

Страница 19: ...e Installation at Installation address Conforms to Directive States that it fulfils the application portion of the following standard Date Location of signature Signature of the person legally responsibility This completed document forms part of the European conformity CE marking to be completed by installer and forwarded to end user Evolve 80kg Evolve SIM Kit Evolve Glass 2006 42 CE Machinery dir...

Страница 20: ...Must be kept for ten years from installation date ...

Страница 21: ... details of the motorized door or gate The installer should apply hazard area notices required by applicable regulations such as that shown below The installer must affix and complete the data tag supplied to the final installation in a suitable prominent position ...

Страница 22: ...on of component factors Maintenance interval Planned replacement schedule Tension wheel assembly 668640 Supports belt movement within machine Cracking excessive wear slipping From New Six months once a year thereafter Every 10 Years of service Wheel cover 668323 Moving part protective cover Cracking excessive wear slipping From New Six months once a year thereafter Toothed belt 668605 Provides mov...

Страница 23: ... Or sooner dependent upon operating conditions Replacement only recommended when apparent excessive wear affects the performance of the installation ...

Страница 24: ...el Description Dimension and Weight Location List of Components Installed Motor Drive Unit Switch Remote fob Motion detector Sign off Check Sheet Warning of residual risks and of foreseeable improper use Inform the end user of risk points regarding risk and foreseeable improper risks Declaration of conformity filled out CE Label completed installed in suitable location Warning sings installed in s...

Страница 25: ...Details Details Installation Start Up Adjustments Maintenance Repairs Alterations Installation Start Up Adjustments Maintenance Repairs Alterations Installation Start Up Adjustments Maintenance Repairs Alterations Installation Start Up Adjustments Maintenance Repairs Alterations Description of the work ...