Three types of transmitters are available, 1, 2 or 3 buttons, therefore up to three doors each fitted with a standard RS 1 control unit can
be controlled independently using a single transmitter. Simply select the transmitter button you wish to use with a particular door and
programme the transmitter as per section 7 “Adding Transmitters”.

16.1 Safety reverse check ;-Once a month check the system for correct operation. Using a transmitter or the operating button open
the door, stand inside the garage, close the door and whilst it is moving block the photo beam (using a piece of cardboard or similar)
The door should stop and then reverse either partially or to the fully open position depending on Dip switch 2 setting. The red LED
indicator should flash quickly when the photocell is blocked.

16.2 Keep the photo sensor lens and reflector clean using a soft damp cloth.

16.3 Keep the RS1 control unit and lens clean, occasionally wipe with a soft damp cloth.
.

The circuit board incorporates a built on aerial for the remote control receiver which is ideal for most applications.

15.1 An optional aerial is supplied which can be fitted as follows: Pass the 135mm stainless steel wire aerial through the small hole in
the base of the RS1 control unit and connect to the terminal marked “EXT A”. Snip the wire link marked “A” on the circuit board, this
is located on the right hand side of the board just above the receiver card.[see Fig 3]

15.2  It is also possible to fit a 'remote' aerial. Connect via coax cable with the inner to terminal “EXT A” and the screen to terminal
“SC”, again snipping link “A”[see Fig 3]

In some instances it may be helpful to switch off the controls operating the door temporarily without turning off the mains power supply
or erasing transmitter security codes. [For example during holiday periods].To activate this feature simply press and hold the operating
button for approximately 12 seconds and wait until the red indicator LED flashes slowly. To return to normal operation switch off the
power supply to the control unit for five seconds and then switch back on.

The microprocessor monitors the circuit board , low voltage control wiring, control devices connected to the system and photoelectric
sensor[s] and detects possible faults. If a fault is detected the door cannot be operated and the red LED will flash slowly. The power
supply should be switched off until the fault is found and corrected

If the safety input is active, the system automatically switches to “Photoelectric Cell Override Mode” which enables controlled closure of
the door in “dead-man” operation. Using a hand transmitter or the built-on operating button and with the door in full view press and
continue to hold the button.The red LED indicator will change state from flashing to on.The button is monitored and after five seconds the
door will close in “deadman” control. Releasing the button will stop the door and the above procedure can be repeated to continue closing
the door Activation of the safety circuit is indicated by the red LED which will flash quickly, this could be due to;- A loose or poor connection
to terminals -Ve, +Ve , S1 or S2. A dirty photocell sensor lens or reflector.. Poor alignment of the photoelectric sensor and reflector.

Multi-door Control - 

11

Photoelectric Cell Overide - 

12

Fault Diagnostic System

.

13

Control Inhibit Feature

.

14 

Fitting the Optional Aerial

.

15

Maintenance

.

16

Содержание Ansa RS1

Страница 1: ...are suitable for the application and are all working satisfactorily This will permit the nominated person to attach a CE label identifying the name of the installing company a unique door reference nu...

Страница 2: ...Installation Instructions Insulated roller door and Compact insulated roller door remote control unit March 2007 Insulated Roller Garage Doors...

Страница 3: ...e read these instructions carefully prior to commencing installation of the unit Operate unit only when the door is in full view and free from any obstruction No one should enter or leave the garage w...

Страница 4: ...lectronics monitor the motor drive and limit switches and turn off the motor run timer as soon the door reaches a fully open or a fully closed position There is no need to wait for the run time to exp...

Страница 5: ...s are used they should be the same type OPERATION The safety beam has no effect on an opening door Breaking the safety beam prevents closure of an open door and will also stop and re open a closing do...

Страница 6: ...close circuit board LED S if necessary switch off the mains power supply and interchange the motor cables at L1 and L2 Note the motor unit has an inbuilt thermal trip which activates if the motor get...

Страница 7: ...Figure 6 Connection diagram Installing 2 photoelectric cell units Figure 7 Connection diagram Option controls...

Страница 8: ...important that the photo beam is centred on the reflector using the following set up procedure Adjust fixing screws A B so that the photoelectric sensor and pivot bracket can be moved up and down and...

Страница 9: ...en switched on selects partial retract If the photocell is activated the door retracts 200mm instead of returning to the fully open position 10 3 Dip switch 3 Security When switched on extends the mot...

Страница 10: ...ig 3 In some instances it may be helpful to switch off the controls operating the door temporarily without turning off the mains power supply or erasing transmitter security codes For example during h...

Страница 11: ...nk wire interconnecting terminals Com Stp if fitted If a stop control device is fitted check the operation and condition of cables connecting this to terminals Com Stp 17 3 Faulty operation the Red in...

Страница 12: ...e Engineer Comments Technical Specification 18 SupplyVoltage 220 240VAC Transformer Power 3VA Power Relays 12 A 230VAC OperatingTemperature 15 to 55 deg C Enclosure Rating IP 44 Courtesy light 40 watt...

Отзывы: