Henderson Ansa RS1 Скачать руководство пользователя страница 1

U.K. Customer Services Department

Telephone: 0191 377 1441  Facsimile: 0191 377 2972

E-mail: [email protected]

Durham Road, Bowburn, County Durham DH6 5NG, England.  Telephone: 0191 377 0701  Facsimile: 0191 377 1309

www.pchenderson.com

P C Henderson (Ireland) Ltd

West Link Industrial Estate, Kylemore Road, Dublin 10, Ireland.  Telephone: 01626 0444   Fax: 01626 0455

www.pchenderson.ie    E-mail: [email protected]

Declaration of Incorporation

This Declaration of Incorporation has been prepared by the garage
door manufacturer to signify that the accompanying garage door
operator, if installed in accordance with the manufacturer’s detailed
instructions will meet the requirements of EN12453.

It is the responsibility of the installer to ensure that doors and garage
door operators are correctly matched prior to installation. It is also the
responsibility of the installer, legally described as the Responsible
Person, to ensure that a suitably nominated person will confirm that the
power operated door has been installed in accordance with the
instructions provided by both the door and drive unit manufacturer.

It is also the responsibility of the installing company to check after
installation that the power operated door and any safety devices
provided are suitable for the application and are all working
satisfactorily.This will permit the nominated person to attach a CE label

identifying the name of the installing company, a unique door reference
number and a date of completion. The installing company should label
the door and provide the documentation as specified within EN12635.

One copy of the Declaration of Conformity is to be issued to the client
and one copy is to be retained by the installing company, together with
the relevant two Declarations of Incorporation. In accordance with the
requirements of the Machinery Directive and the UK Supply of
Machinery (Safety) Regulations, these records are to be retained on file
for a period of ten years.

Note.
Duplicated printed pads set out in the format of Declarations of
Conformity in order to allow on site completion are available at a
reasonable cost from the DSMA for both members and non-members.
Alternatively, for an additional cost, a technical records file with full
details of requirements and procedures for compliance, and including
the necessary filing divisions, is also available.

SUPPLY OF MACHINERY (SAFETY) REGULATIONS 1992

E.C. DECLARATION OF INCORPORATION

GARAGE DOORS FOR POWERED OPERATION

GARAGE DOORS • SLIDING AND FOLDING DOOR HARDWARE

COMPOSITE ENTRANCE DOORS

P.C. HENDERSON LIMITED, DURHAM ROAD, BOWBURN, DURHAM DH6 5NG.

March 2007

Issue 1 (Insulated Roller Garage Doors)

This declaration is made by:

(V. Brockley, Managing Director)

Содержание Ansa RS1

Страница 1: ...are suitable for the application and are all working satisfactorily This will permit the nominated person to attach a CE label identifying the name of the installing company a unique door reference nu...

Страница 2: ...Installation Instructions Insulated roller door and Compact insulated roller door remote control unit March 2007 Insulated Roller Garage Doors...

Страница 3: ...e read these instructions carefully prior to commencing installation of the unit Operate unit only when the door is in full view and free from any obstruction No one should enter or leave the garage w...

Страница 4: ...lectronics monitor the motor drive and limit switches and turn off the motor run timer as soon the door reaches a fully open or a fully closed position There is no need to wait for the run time to exp...

Страница 5: ...s are used they should be the same type OPERATION The safety beam has no effect on an opening door Breaking the safety beam prevents closure of an open door and will also stop and re open a closing do...

Страница 6: ...close circuit board LED S if necessary switch off the mains power supply and interchange the motor cables at L1 and L2 Note the motor unit has an inbuilt thermal trip which activates if the motor get...

Страница 7: ...Figure 6 Connection diagram Installing 2 photoelectric cell units Figure 7 Connection diagram Option controls...

Страница 8: ...important that the photo beam is centred on the reflector using the following set up procedure Adjust fixing screws A B so that the photoelectric sensor and pivot bracket can be moved up and down and...

Страница 9: ...en switched on selects partial retract If the photocell is activated the door retracts 200mm instead of returning to the fully open position 10 3 Dip switch 3 Security When switched on extends the mot...

Страница 10: ...ig 3 In some instances it may be helpful to switch off the controls operating the door temporarily without turning off the mains power supply or erasing transmitter security codes For example during h...

Страница 11: ...nk wire interconnecting terminals Com Stp if fitted If a stop control device is fitted check the operation and condition of cables connecting this to terminals Com Stp 17 3 Faulty operation the Red in...

Страница 12: ...e Engineer Comments Technical Specification 18 SupplyVoltage 220 240VAC Transformer Power 3VA Power Relays 12 A 230VAC OperatingTemperature 15 to 55 deg C Enclosure Rating IP 44 Courtesy light 40 watt...

Отзывы: