4
Helvar Ltd
Hawley Mill
Hawley Road
DARTFORD
DA2 7SY
UNITED KINGDOM
www.helvar.com
Doc. 7860341, issue 2, 2015-12-15
Helvar
| Data is subject to change without notice.
Conformity and standards
EMC emission:
EN60669-2-1:2004 inc
A12:2010
EMC immunity:
EN60669-2-1:2004 inc
A12:2010
Safety:
EN60669-2-1:2004 inc
A12:2010
Environment:
Complies with WEEE and RoHS
directives.
Version information
Hardware version:
Rev. 1
Hole diameter:
Ø
75 mm
2
60
77
85
Dimensions (mm)
Technical Data
Electrical data
External power:
Terminal block
Wire section: 0.5 mm² –
2.5 mm² solid or stranded
Cable rating:
All cables must be mains
rated.
Mains supply:
230 VAC, 50 Hz
Loads:
6 A resistive (e.g. heater)
4 A incandescent
3 A fluorescent ballast / LED
driver
1 A inductive (e.g. fan/motor)
Mains LED lamps: Equivalent
to 1000 W halogen load
Min. load: 2 W resistive,
suitable for most energy saving
lamps, LEDs and emergency
fittings.
External
protection:
6 A maximum (MCB or fuse)
Illuminance:
10 lx to 1000 lx and maximum
(photocell inactive) at the PIR
switch.
Sensors
Presence detector:
PIR (Passive InfraRed)
Detection range:
360° with up to 7 m diameter
when mounted at a 2.8 m
ceiling height
Time:
10 s to 40 min
Mechanical data
Mounting hole
diameter:
75 mm
Bezel diameter:
85 mm
Recommended
clearance depth
(incl. 50 mm for
cabling):
80 mm (without protective
cover)
100 mm (with protective cover)
Material (casing):
Flame-retardant polycarbonate
Finish / Colour:
Matt / White RAL9003
Weight:
100 g
IP code:
IP20
Operating conditions
Ambient
temperature:
+10 °C to +35 °C
Note: The temperature
difference between the detection
target and the background must
be at least 4 °C.
Relative humidity:
Max. 90 %, noncondensing
Storage
temperature:
–10 °C to +70 °C