background image

4215-109 G                                                                                                                                                                                                                                                            

10/30/09                                                                                                                                                                                                                                                    

                                                                                                                                                                                                                                                          

Page 9

SECTION 6: SAUNALOGIC IS CONTROL INSTALLATION & OPERATION

OPERATING INSTRUCTIONS FOR IR EMITTERS  .
Press the red POWER button once. The Infrared heaters will turn on and begin heating the room to current set 
points.  At the end of the selected time (60 minutes maximum), the control will turn itself off and the control 
display will turn off. The infrared room temperature will be displayed on the control. The default settings for 
Infrared temperature is preset to 120°F, the bath time is set to 60 minutes and 0 minute delay to start to heat. 
These settings are adjustable (as described below) from 110° to 149°. Length of sauna can be set from 0 to 60 
minutes. The time delay before start can be up to 23 hour and 59 minutes 

SETTING THE DURATION AND TEMPERATURE  
To set the sauna length of time, press the control POWER button to turn on the heater.  Press the TIME "+" or 
"-" buttons on the control to increase or decrease time for desired setting. The maximum of time is 60 
minutes.

To set the temperature, press the control POWER button to turn on the heater.  Press the TEMP "+" or "-" 
buttons on the control to increase or decrease temperature for desired setting. The maximum temperature is 
149°F (65°C). 

Note: Typical bathing temperature is 115F to 125F displayed on the control. Starting ambient temperature 
below 70F will cause the IR system to heat slower, which may result in less effective performance.

Press the Traditional Sauna button on the SaunaLogic IS and the default settings for the temperature is preset 
to 176°F, the bath time is set to 60 minutes and 0 minute delay to start to heat.  These settings are adjustable 
(as described below) from 125° to 194°. Length of sauna can be set from 0 to 60 minutes. The time delay 
before start can be up to 23 hour and 59 minutes. 

SETTING THE DURATION AND TEMPERATURE  
To set the sauna length of time, press the red POWER button to turn on the heater and press the 
TRADITIONAL sauna button.  Press the TIME "+" or "-" buttons on the SaunaLogic IS to increase or 
decrease time for desired setting. The maximum of time is 60 minutes.

To set the temperature, press the control POWER button to turn on the heater.  Press the TEMP "+" or "-" 
buttons on the SaunaLogic IS to increase or decrease temperature for desired setting. The maximum 
temperature is 194°F (90°C). 

Note: Typical bathing temperature is 150F to 165F displayed on the control.

PRE-SETTING DELAYED START
With the electricity applied to the CB PK box, press the SaunaLogic IS POWER button once.  The room 
temperature will be displayed on the control.  Press the “Pre-setting” button. Press the TIME "+" or "-" 
buttons on the control to increase or decrease delay time for desired setting. The maximum of time is 23 hours 
and 59 minutes. If no delay start is desired, set to 00:00 and press “Pre-Setting” button. 

Note: The “   ” will flash between the numbers in the time display when system is in the delayed start mode.

Содержание IS 200

Страница 1: ...gets hot during operation and should not be touched or burns may result Minors should be adequately supervised whenever near a hot or warming sauna Infrared Sauna Series Models IS 200 IS 300 IS 400 I...

Страница 2: ...materials to be sure you have the proper minimum distances DIAGRAM 2 Page 2 OBSERVING MINIMUM DISTANCES IS REQUIRED TO REDUCE FIRE HAZARD Sauna Heater Optional Equipment Sauna Heater Denotes an option...

Страница 3: ...4215 109 G 10 30 09 Typical IS Installation with a tradiontal sauna heater Refer to Diagram 1 for minimum spacing requirements...

Страница 4: ...ize information Step 3 Will the wires be installed in the walls or surface mounted If preinstalled pull 12 2 AWG wire w ground from the CB PK Box to closest IR emitter Leave 18 of wire sticking out th...

Страница 5: ...allation Optional Equipment SaunaLogic IS is capable of operating ONLY a lighting package purchased with the system The lighting package consists of 3 color therapy lights 2 interior lights 3 exterior...

Страница 6: ...Interior Lights Connect the cable from exterior lights to the connector labels Exterior Lights Connect the high limit sensor cable to JT13 of the circuit board in the CB PK Box Traditional sauna heat...

Страница 7: ...4215 109 G 10 30 09 Page 7 WIRING DIAGRAM CONTROL AND HEATER MODELS...

Страница 8: ...4215 109 G 10 30 09 Page 8 WIRING DIAGRAM CONTROL AND HEATER MODELS...

Страница 9: ...stem to heat slower which may result in less effective performance Press the Traditional Sauna button on the SaunaLogic IS and the default settings for the temperature ispreset to 176 F the bath time...

Страница 10: ...igh limit continually shuts off the heater contact a service representative at 1 888 780 4427 The sauna like a bathroom should be kept clean and odor free Towels or mats should always be used on bench...

Страница 11: ...ed WARNING Reduce the risk of overheating warning plate must be mounted on or alongside the door outside the sauna room at about eye level The enclosed CAUTION Reduce the risk of fire caution plate mu...

Страница 12: ...rmation There is one high limit for each system Need to determine which system is operating to know which high limit is alarming System won t start to heat ensure the system is not in the delay mode I...

Отзывы: