background image

4215-109 G                                                                                                                                                                                                                                                            

10/30/09                                                                                                                                                                                                                                                    

                                                                                                                                                                                                                                                          

DIAGRAM 1

MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL

Recheck your distances from the heater to 
combustible  materials to be sure you have the 
proper minimum distances. 

DIAGRAM 2

Page 2

OBSERVING MINIMUM DISTANCES IS 
REQUIRED TO REDUCE FIRE HAZARD

*Sauna Heater

Optional

Equipment

Sauna Heater

* Denotes an optional traditional sauna heater may be added to 
the system. Refer to Installation and Operation manual for 
installation questions.

Содержание IS 200

Страница 1: ...gets hot during operation and should not be touched or burns may result Minors should be adequately supervised whenever near a hot or warming sauna Infrared Sauna Series Models IS 200 IS 300 IS 400 I...

Страница 2: ...materials to be sure you have the proper minimum distances DIAGRAM 2 Page 2 OBSERVING MINIMUM DISTANCES IS REQUIRED TO REDUCE FIRE HAZARD Sauna Heater Optional Equipment Sauna Heater Denotes an option...

Страница 3: ...4215 109 G 10 30 09 Typical IS Installation with a tradiontal sauna heater Refer to Diagram 1 for minimum spacing requirements...

Страница 4: ...ize information Step 3 Will the wires be installed in the walls or surface mounted If preinstalled pull 12 2 AWG wire w ground from the CB PK Box to closest IR emitter Leave 18 of wire sticking out th...

Страница 5: ...allation Optional Equipment SaunaLogic IS is capable of operating ONLY a lighting package purchased with the system The lighting package consists of 3 color therapy lights 2 interior lights 3 exterior...

Страница 6: ...Interior Lights Connect the cable from exterior lights to the connector labels Exterior Lights Connect the high limit sensor cable to JT13 of the circuit board in the CB PK Box Traditional sauna heat...

Страница 7: ...4215 109 G 10 30 09 Page 7 WIRING DIAGRAM CONTROL AND HEATER MODELS...

Страница 8: ...4215 109 G 10 30 09 Page 8 WIRING DIAGRAM CONTROL AND HEATER MODELS...

Страница 9: ...stem to heat slower which may result in less effective performance Press the Traditional Sauna button on the SaunaLogic IS and the default settings for the temperature ispreset to 176 F the bath time...

Страница 10: ...igh limit continually shuts off the heater contact a service representative at 1 888 780 4427 The sauna like a bathroom should be kept clean and odor free Towels or mats should always be used on bench...

Страница 11: ...ed WARNING Reduce the risk of overheating warning plate must be mounted on or alongside the door outside the sauna room at about eye level The enclosed CAUTION Reduce the risk of fire caution plate mu...

Страница 12: ...rmation There is one high limit for each system Need to determine which system is operating to know which high limit is alarming System won t start to heat ensure the system is not in the delay mode I...